If a Protector Cap is fitted, it must be removed before the unit is

switched on. Remove the cap by turning it anti-clockwise until the

cap bayonets can be lifted out of the reflector bayonet slots (the

Reflector Release Button may have to be slid back).

NEVER OPERATE THE LAMP OR THE FLASH WHILE THE

PROTECTOR CAP IS FITTED.

Damage to the unit could occur if the cap melts due to the heat from

the flash-tube or lamp.

Replace the Protector Cap when the unit is not in use.

6

Reflectors and other accessories (such as

Soft Boxes) can be fitted to the unit by

way of the three Reflector Bayonet Slots.

When fitting any accessories, do not

allow anything to touch the flash-tube.

The glass flash-tube can be damaged or

broken if it comes into contact with any

accessory.

It is preferable to fit the modelling lamp

after fitting the accessory, if it is

possible.

Line up the reflector bayonets over the

slots, as shown. If an umbrella reflector

is also going to be used, orientate the

reflector so that the oblong reflector slot

is at the bottom of the unit.

Engage the reflector bayonets and turn

the reflector until it stops. For security of

fitting, slide back the Reflector Release

Button and turn the reflector further.

At this point, the oblong reflector slot should be in line with the unit's umbrella clamp; if an umbrella is

going to be used, the umbrella shaft should pass through the reflector and into the slot of the umbrella

clamp. Note: When inserting the umbrella shaft, do not allow it to touch the flash-tube; damage to the

tube may occur. Always clamp the shaft into place using the Umbrella Clamp Screw (do not over-tighten

this screw; distortion damage to the shaft may occur).

To release the reflector, first remove the modelling lamp, if fitted. Turn the reflector anti-clockwise and,

at the same time, slide back the Reflector Release Button.

Reflector Fitting

Summary of Contents for lumen 8

Page 1: ...User Manual...

Page 2: ...ctor 2 Reflector Release Button 3 Slave Cell 4 Lighting Stand Clamp 5 Clamp Screw 6 Umbrella Clamp Screw 7 Umbrella Clamp 8 Reflector Umbrella Slot 9 Inner Reflector 10 Flash Tube 11 Reflector Bayonet...

Page 3: ...Power Socket 14 Fuseholder Fuses 15 Power On Off 16 Modelling Lamp On 17 Modelling Lamp Full 18 Slave Cell On 19 Beeper Sounder On 20 Flash Test Button 21 Ready to Fire Indicator 22 Flash Modelling P...

Page 4: ...th one hand while adjusting the tilt with the other OPERATING PRECAUTIONS SAFETY The F200 400 units are designed for indoor use only and for connection to domestic 220 240VAC single phase only The uni...

Page 5: ...sory if it is possible Line up the reflector bayonets over the slots as shown If an umbrella reflector is also going to be used orientate the reflector so that the oblong reflector slot is at the bott...

Page 6: ...are when fitting a lamp 11 The ES screw socket may require the lamp to be fully screwed down in order to make contact If a new lamp fails to light check that it is fully screwed down 12 Take care not...

Page 7: ...his function the photographer can easily check from the camera position that all units have flashed When the Full switch is switched up the modelling lamp function changes the lamp will stay on when t...

Page 8: ...ll increase the flash by another one stop approximately double the light Mid way positions can be used for increases in light of less than one stop the control has small click indents to aid fractiona...

Page 9: ...be flashed Do not try to fire the unit before this indicator is lit When firing the unit at short intervals refer to the maximum advisable flash rate firing the unit too quickly can cause the flash tu...

Page 10: ...3AL For convenience all flash units are provided with a spare fuse built into the fuse holder The following procedure must be taken to replace the fuse 11 Fuse Replacement The fuse holder is accessed...

Page 11: ...amp Modes Full Prop Off Full Prop Off Auto Dump Yes Yes Colour Temperature 5300 5600k 5300 5600k Slave Cell Yes 10 metres Yes 10 metres Triggering Methods Sync Test Slave Sync Test Slave Main Operatin...