background image

Manual 

 5 / 7 

Revision: Apr-10 

 

Patterns:

 160 

 

Scanangle:

 set to ca. 40° optical (60° max) 

 

Input voltage:

 AC 110-120, 220-240V switchable 

50/60Hz 

 

Power consumption:

 450W 

 

Size:

 800 x 530 x 350mm (W x D x H) 

 

Weight:

 69kg Laser, 

total:

 96kg 

(with 

flightcase)

 

 

Operating temperature:

 10°-35°C 

 

Loudness:

 <70db 

Change scanner 

1.

 

Unscrew UK M6 screws and disconnect signal 
cable. 

2.

 

Loosen M4 x 10 screw and remove galvo.  

3.

 

Insert galvo, reconnect and fix signal cable. 

4.

 

Rotate galvo to center projection. Fix galvo. 

Adjustable mirror mounts 

Loosen setscrews, then adjust with X/Y adjustable screws. Make 

sure beam is centered on scanner mirrors. Adjust Z-screw 
simultaneously Tighten setscrews. 

When combining beams (RGY/RGB laser), first make sure the beams 
are (roughly) on the same spot on the mirrors/dichros. Then use a 
test pattern (e.g. rectangle) to do fine adjustment. For adjustments, 

always turn output power down (if possible). 

Troubleshooting 

Problem 

Possible reason 

Damaged part 

Replacement 

No power 

Fuse blown 

Fuse 

09-00-3001-01 

Power supply defective 

+-24V 

16-03-0039-00 

Music mode not working 

Microphone defective 

Microphone 

16-03-0001-00 

Control board defective 

Control board 

26-2A-LT12V2-00 

Potentiometer defective 

Potentiometer 

04-03-0104-01 

CPU defective 

IC 

00-89C516RD-00 

 

 

X and/or Y axis no 

deflection 

 

Scanner defective 

Galvo 

15-01-2215-00 

CPU defective 

IC 

00-89C516RD-00 

 Control board defective 

Control PCB 

26-2A-LT12V2-00 

Power supply defective 

+-24V 

16-03-0039-00 

Scanner driver board defective 

Scanner driver board  

26-2A-6800A-00 

 
 

Laser dark or dim 

Lenses / mirrors dirty 

Clean with alcohol 

 

Laser diode defective 

Laser diode 

Inquire 

Control board defective 

Control board 

26-2A-LT12V2-00 

Configuration / wrong mode 

Check configuration (see 
paragraph control panel) 

 

 

 

 

No output 

Configuration / wrong mode 

Check configuration (see 
paragraph control panel) 

 

 Control board defective 

Control PCB 

26-2A-LT12V2-00 

Power supply defective 

+-24V 

16-03-0039-00 

Display board defective 

Display 

26-2A-YX2012DI-00 

Pins 4 and 17 of the ILDA signal 

not connected 

See below 

 

Laser does not switch to ILDA mode:  

 

The interface does not connect pins 4 and 17 (Interlock) of the ILDA signal. See interface manual 

 

The cable does not connect pins 4 and 17. Use a cable that connects pins 4 and 17. 

 

Use an adapter, that connects pins 4 and 17. 

ILDA signal 

Pin out of the standard ILDA signal: 

1 Scanner X+  

-5V..+5V 

14 X- 

+5V..-5V 

2 Scanner Y+  

-5V..+5V 

15 Y- 

+5V..-5V 

3 Intensity/B 

 0V..+2.5V 

16 Intensity/Blanking- 

0..-2.5V 

4 Interlock A 

 

17 Interlock B 

5 Red+  

0..2.5V 

18 Red- 

0..-2.5V 

Reviews: