Manual
5 / 7
Revision: Apr-10
Patterns:
160
Scanangle:
set to ca. 40° optical (60° max)
Input voltage:
AC 110-120, 220-240V switchable
50/60Hz
Power consumption:
450W
Size:
800 x 530 x 350mm (W x D x H)
Weight:
69kg Laser,
total:
96kg
(with
flightcase)
Operating temperature:
10°-35°C
Loudness:
<70db
Change scanner
1.
Unscrew UK M6 screws and disconnect signal
cable.
2.
Loosen M4 x 10 screw and remove galvo.
3.
Insert galvo, reconnect and fix signal cable.
4.
Rotate galvo to center projection. Fix galvo.
Adjustable mirror mounts
Loosen setscrews, then adjust with X/Y adjustable screws. Make
sure beam is centered on scanner mirrors. Adjust Z-screw
simultaneously Tighten setscrews.
When combining beams (RGY/RGB laser), first make sure the beams
are (roughly) on the same spot on the mirrors/dichros. Then use a
test pattern (e.g. rectangle) to do fine adjustment. For adjustments,
always turn output power down (if possible).
Troubleshooting
Problem
Possible reason
Damaged part
Replacement
No power
Fuse blown
Fuse
09-00-3001-01
Power supply defective
+-24V
16-03-0039-00
Music mode not working
Microphone defective
Microphone
16-03-0001-00
Control board defective
Control board
26-2A-LT12V2-00
Potentiometer defective
Potentiometer
04-03-0104-01
CPU defective
IC
00-89C516RD-00
X and/or Y axis no
deflection
Scanner defective
Galvo
15-01-2215-00
CPU defective
IC
00-89C516RD-00
Control board defective
Control PCB
26-2A-LT12V2-00
Power supply defective
+-24V
16-03-0039-00
Scanner driver board defective
Scanner driver board
26-2A-6800A-00
Laser dark or dim
Lenses / mirrors dirty
Clean with alcohol
Laser diode defective
Laser diode
Inquire
Control board defective
Control board
26-2A-LT12V2-00
Configuration / wrong mode
Check configuration (see
paragraph control panel)
No output
Configuration / wrong mode
Check configuration (see
paragraph control panel)
Control board defective
Control PCB
26-2A-LT12V2-00
Power supply defective
+-24V
16-03-0039-00
Display board defective
Display
26-2A-YX2012DI-00
Pins 4 and 17 of the ILDA signal
not connected
See below
Laser does not switch to ILDA mode:
The interface does not connect pins 4 and 17 (Interlock) of the ILDA signal. See interface manual
The cable does not connect pins 4 and 17. Use a cable that connects pins 4 and 17.
Use an adapter, that connects pins 4 and 17.
ILDA signal
Pin out of the standard ILDA signal:
1 Scanner X+
-5V..+5V
14 X-
+5V..-5V
2 Scanner Y+
-5V..+5V
15 Y-
+5V..-5V
3 Intensity/B
0V..+2.5V
16 Intensity/Blanking-
0..-2.5V
4 Interlock A
17 Interlock B
5 Red+
0..2.5V
18 Red-
0..-2.5V