Power consumption:
450W
•
Size:
800 x 530 x 350 mm (W x D x H)
•
Weight:
69kg Laser,
total:
96kg
(with flightcase)
•
Operating temperature:
10°-35°C
•
Loudness:
<70dB
Change scanner
1.
Unscrew UK M6 screws and disconnect
signal cable.
2.
Loosen M4 x 10 screw and remove galvo.
3.
Insert galvo, reconnect and fix signal
cable.
4.
Rotate galvo to center projection. Fix
galvo.
Adjustable mirror mounts
1.
Loosen setscrews, then adjust with X/Y
adjustable screws. Make sure beam is
centered on scanner mirrors.
2.
Adjust Z-screw simultaneously.
3.
Tighten setscrews.
4.
When combining beams (RGY/RGB laser),
first make sure the beams are (roughly)
on the same spot on the mirrors/dichros.
Then use a test pattern (e.g. rectangle) to
do fine adjustment. For adjustments,
always turn output power down (if
possible).
Troubleshooting
Problem
Possible reason
Damaged part
Replacement
No power
Fuse blown
Fuse
09-00-3001-01
Power switch defective
Power switch
08-05-0400-03
Power supply defective
+-24V
16-03-0039-00
Power supply defective
12V
16-03-0019-00
X and/or Y axis no
deflection
Scanner defective
Galvo
15-01-6800-00
CPU defective
STC89C516
00-89C516ED-00
Control board defective
Steuerung PCB
26-2A-2009LD-00
Power supply defective
+-24V
16-03-0039-00
Scanner driver board defective
Scanner driver board
26-2A-6800A-00
Laser dark or dim
Lenses / mirrors dirty
Clean with alcohol
Laser diode defective
Laser diode
Inquire
Control board defective
Control board
26-2A-2009LD-00
Configuration / wrong mode
Check configuration (see
paragraph control panel)
No output
Configuration / wrong mode
Check configuration (see
paragraph control panel)
Control board defective
Steuerung PCB
26-2A-2009LD-00
Power supply defective
+-24V
16-03-0039-00
Display board defective
Display
26-2A-YX2012DI-00
Pins 4 and 17 of the ILDA signal
not connected
See below
Laser does not switch to ILDA mode:
•
The interface does not connect pins 4 and 17 (Interlock) of the IDLA signal. See interface manual
•
The cable does not connect pins 4 and 17. Use a cable that connects pins 4 and 17.
•
Use an adapter, that connects pins 4 and 17.