background image

User manual: Pro-4000RGB 

Rev: Sep/2010 

page 3 of 8

Warning labels on the device 

Laser radiation 

Read manual  

 

before use 

Avoid exposure 

Operation by qualified 

To the beam 

personal only 

Laser class 4 

Never direct laser  

 

Beam at people 

Caution of radiation 

Never look directly  

If cover is removed 

into beam  

 
Indoor use only 
At front opening:  

Avoid exposure – laser radiation is emmited. 

OPERATING THE LASER 

Don’t remove the warranty/serial number label - removal voids warranty 
The operator has to make sure that laser radiation – for laser class 4 also reflected laser radiation – 
higher than the maximum permissible level is avoided by technical or organisational measures. 
(Especially with respect to the MPE, see above.) 
Make sure to use the correct voltage. Use a power socket with earth/ground. 

Don’t use dimmer, 

RC,

 or other 

electronically switched

 sockets. Whenever possible, don’t use the laser together with 

large appliances, especially fog machines, on the same mains! 
If the device is used in a flying installation, the mounting brackets and an appropriate safety-rope 
must be afixed. 
In some countries, the operator must notify the accidence insurance and the authority for industrial 
safety, before operating a laser. For more information, contact the relevant authorities. 
Please consider that unauthorized modifications on the device are strictly forbidden due to safety 
reasons! 
If this device will be operated in any way differently than described in this manual, the product may 
suffer damages and the guarantee becomes void. Furthermore, any other operation may lead to 
dangers like short-circuit, burns, electric shock, etc. 
Keep surrounding dry and clean. T

his unit should be keep dry, do not use in the rain or damp and 

dusty environment, don’t put liquid fileld containers on the device. Projector should be put in a water-
proof housing when operated outside.  
Regularly open the device (see “cleaning” further down) to check for dust inside, or if fog fluid 
condenses in the housing (if so rearrange hazer and/or laser position). 
Operating temperature is 10~35

°C

. In a new installation, check after some 15-30 minutes whether 

the outlet air gets too warm. Regularly check the inside for dust deposits, especially around the fans. 
Let laser cool off 10minutes after 2 hours of operation,to ensure maximum lifetime for the diode. 
Distance between laser aperture and projection screen should be not less than 1 meter. 
Do not turn device on and immediately off again frequently. 
Do not look into the laser beam directly, especially not with optical instruments. 

Do not touch the device with wet hands. 

When the laser diode becomes dim or broken, please contact your dealer. 
When returning laser to dealer/manufacturer always use original packaging.

 

Maintenance should be performed every 15-day period. See “cleaning” further down. 

To ensure maximum lifetime of the laser: 
Don’t overheat the laser: 

 

Always ensure good ventilation 

 

Don’t have stage lights (especially moving heads) directed towards the laser 

 

Regularly clean the fans and the interior from dust 

 

In a new installation check the temperature after 30 minutes of operation 

Keep the laser dry 

 

Make sure fog/hazer fluid doesn’t condensate inside the laser - fog has to be in front of the 
laser – not inside 

 

A few days after (each new) installation, open the cover to check if fluids condensate inside 

 

If fluids condensate inside, reposition the laser or fogger/hazer 

Turn the device off, when not used. The diode is on, when the device is on. Even if it is not lit. 

Summary of Contents for Pro-4000RGB

Page 1: ...Pro 4000RGB User Manual Please read this manual carefully before use...

Page 2: ...der to safeguard sufficient ventilation leave 50 cm of free space around the device Never direct the laser beam to people or animals CAUTION LASER DIODE If you open the device for cleaning always disc...

Page 3: ...clean This unit should be keep dry do not use in the rain or damp and dusty environment don t put liquid fileld containers on the device Projector should be put in a water proof housing when operated...

Page 4: ...me out of the opening on the front panel be careful Connectors Control panel MODE select mode or go up in menu ENTER confirm changes or go down in menu UP DOWN change DMX address Operating modes DMXAd...

Page 5: ...eed 0 255 slow to fast 16 Point draw 0 255 slow to fast 17 Scanspeed 0 255 slow to fast 18 Pattern size 0 1 Original size 2 255 Change Maintenance cleaning Always disconnect from mains before cleaning...

Page 6: ...switch 08 05 0400 03 Power supply defective 24V 16 03 0039 00 Power supply defective 12V 16 03 0019 00 X and or Y axis no deflection Scanner defective Galvo 15 01 6800 00 CPU defective STC89C516 00 8...

Page 7: ...V 5V 14 X 5V 5V 2 Scanner Y 5V 5V 15 Y 5V 5V 3 Intensity Blanking 0V 2 5V 16 Intensity Blanking 0 2 5V 4 Interlock A 17 Interlock B 5 Red 0 2 5V 18 Red 0 2 5V 6 Green 0 2 5V 19 Green 0 2 5V 7 Blue 0 2...

Page 8: ...ions and unskilled operation For service contact your dealer or Laserworld Only use Laserworld spare parts Data subject to change without notice Errors and omissions expected Laserworld Switzerland AG...