Manual: PL-3000RGB
NL
/ PL-6000RGB
NL
/ PL-12.000RGB
NL
page 16 / 34
Set mode between Liveshow and Player
In the upper section of the Show Management, mode can be set by NetLase. To control play-
er by DMX select „NetLase starts in Player Mode“. Select „Apply“ take settings. Restart card to
take setting. Setting remains until selection of „NetLase starts in Live-Mode“.
Note: Don‘t forget the switching of the setting. To control NetLase via DMX, without a PC,
player mode has to be activated. Otherwise NetLase cannot react to DMX signals. If „Live“
mode is not selected, NetLase can‘t react to the software of PC (e.g. Phoenix, Mamba, or HE-
Laserscan).
If all files are set in Show management, the wiring of DMX has to be selected.
11. Fault Finding:
Situation
Reason
Faulty Part
Parts Number
No power for the
motor
fuse fault
Fuse
09-00-2001-01
power supply fault
+-24V
16-03-0039-00
PCB control fault
PCB Control
26-2A-LT12V2-00
Potentiometer fault
Potentiometer
04-03-0104-01
PCB IC control fault
IC
00-89C516RD-00
X, Y scanners
don‘t move; no
patterns or jigg
-
ling scanners
scanner fault
scan motor
15-01-2215-00
PCB IC control fault
IC
00-89C516RD-00
PCB control fault
PCB Control
26-2A-LT12V2-00
power supply fault
+-24V
16-03-0039-00
scanner driver fault
scanner driver
26-2A-6800A-00
No light output;
weak light output
or no closed la-
ser beam, other
functions are
working
dirty mirrors
clean with alcohol
laser diode fault
Please ask
PCB control fault
PCB control
26-2A-LT12V2-00
device configuration fault
Check the configu
-
ration (see device
operation)
No control pos-
sible other funk
-
tions are working
(e.g. laser diode
or ventilation)
device configuration fault
see above
PCB conrol fault
PCB control
26-2A-LT12V2-00
power supply fault
+-24V
16-03-0039-00
PCB display fault
PCB display
26-2A-LT228DI-00
PCB IC control fault
IC
00-STC89C54RD-00
It is not possible to control the device by ILDA: