52
please move opposite
direction"
2.
Check that the Z-limit
switch sensor is
working properly.
3.
Continue work or lower
the Z-platform if
necessary.
"PCL Command Error
Command: Address:
Please press any key to
stop"
The firmware on the
machine and the application
driver is not compatible.
1.
Find out the firmware
and driver versions that
are being used.
2.
Upgrade to the most
up-to-date firmware and
driver versions or use
compatible versions.
"Error! Please check the
lens carriage position under
relative mode"
The output object is out of
the working area and cannot
be outputted.
1.
Check that the output
object can be outputted
on the working area
under the correct
position mode.
2.
Adjust the pen carriage
to an open area. For e.g
Origin point for relative
mode or center of the
table for Center mode.
3.
Restart the job.
"No Language Data Display
in English Please download
language data first"
The file that contains the
Language data is missing.
1.
Set the language back
to English.
2.
Upload the missing
language file to the
machine.
3.
Set the language mode
to the desired language
again.
"Storage total file size out
of 4M bytes. Please remove
some file"
The file being stored
exceeds the 4M size limit.
1.
Reduce the size of file
to be stored to below
4M.
2.
Save the file again.
Distributed & Supported by: Jorlink USA, Inc. | Tel: (336) 288-1613 | [email protected] | www.JORLINK.com
53/60