background image

LED Ultra Sign Instruction Manual 

 

00625-53-000 

Page 13 of 13

 

Issue 4.1          19 January 2021 

 

Contact Details 

 
Lasermet provide a full range of laser interlock equipment including interlock switches, illuminated 
warning signs, laser shutters, entry keypads with built-in fail-safe override timer, door locks, external 
power  supplies  etc.  which  can  be  interconnected  to  provide  a  complete  system.  We  also  supply 
equipment and consultancy covering all aspects of laser safety. Full support, design, and installation 
is available from Lasermet, please contact us for any queries.  
 
 
 

For sales and technical support: 

 
 

Lasermet Ltd. 

Lasermet House, 
137 Hankinson Road, 
Bournemouth 
BH9 1HR 
United Kingdom. 

 

Tel: 

+44 (0) 1202 770740 

Fax: 

+44 (0) 1202 770730 

 

Email:   

[email protected] 

Website: 

www.lasermet.com 

 
 
 

Lasermet Inc. 

10N Martingale Road, Suite 400, 
Schaumburg, Illinois 60173 
United States. 

 

Tel: 

847 466 1475 

 

Email:   

[email protected] 

Website: 

www.lasermet.com 

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for ULTRA LEDS-ULT-470

Page 1: ...LEDS Ultra Sign Instruction Manual 00625 53 000 Issue 4 1 19 January 2021 LASERMET ULTRA LED SIGN INSTRUCTION MANUAL SINGLE AND DUAL ASPECT ILLUMINATED SIGN LEDS ULT 470 and LEDS ULT 790 ...

Page 2: ...of 13 Issue 4 1 19 January 2021 LASERMET LED Ultra Sign Instruction Manual Contents 1 Declaration of Conformity 3 2 Safety Warnings 4 3 Concept 5 4 Installation 6 5 Wiring 9 5 1 Sign Good Indicators 11 6 Specifications 12 7 Warranty 12 8 Contact Details 13 ...

Page 3: ...as been tested in accordance with the following directives and standards and found to comply Lasermet certifies that this product complies with the basic requirements for health and safety as provided by the following directives and standards Directives Low Voltage Directive 2014 35 EU EMC Directive 2014 30 EU CE Directive 93 68 EEC Standards EN 60598 1 2008 EN 62471 2008 EN 55015 2006 EN 61547 19...

Page 4: ...ade to tamper with the parts open them or use them outside of the parameters contained herein The units are only designed to be fixed to surfaces using their inbuilt fixing holes They must not come into contact with each other or any other moving part when in use The parts should never be subject to impact or mechanical strain Safety switches should never be defeated or bypassed It is imperative t...

Page 5: ...ety within the sign and supply wiring compared to a mains supply The sign has a dimming option which can be configured to reduce the brightness and power consumption of the sign This may be achieved either automatically according to the light falling on an internal sensor or by applying a separate brightness control voltage to the sign The message is almost invisible when the sign is switched off ...

Page 6: ...he driver board It is then easier to slide the front panel across the top It is most important that the components on the driver board are not dislodged or bent as otherwise they will not align with the apertures in the graphics film This will impair the operation of the sign The preferred cable entry to the sign is via the Ø20mm hole provided in the rear top centre of the sign When directly wall ...

Page 7: ...holes may be cut if required The trays allow convenient hook on mounting and electrical connection to the signs To attach the signs to the wall tray start with the bottommost sign hang it on the hooks provided on the wall tray and secure using two M4 X 12 screws in the bottom two fixing holes in the sign Make the wiring connections next then lay a joining strip along the top of the first sign befo...

Page 8: ...LED Ultra Sign Instruction Manual 00625 53 000 Page 8 of 13 Issue 4 1 19 January 2021 Figure 3 Mounting Arrangement using 4 way Wall Tray ...

Page 9: ... just one driver board It is preferable for the negative 0V of the power supply to be connected to earth at the source To eliminate the potential for static electrical damage to the sign circuitry the 0V terminal of each driver board is connected to the casing of the sign through a 100Ω resistor The sign contains no hazardous voltages and it is not normally necessary to provide a dedicated earth c...

Page 10: ...n Manual 00625 53 000 Page 10 of 13 Issue 4 1 19 January 2021 Figure 4 Terminal Identification Figure 5 Connections for dual drivers using two power supplies Figure 6 Connections for one way dual drivers using one power supply ...

Page 11: ... connections if not fitted Figure 8 Two way Sign Control 5 1 Sign Good Indicators Each driver board has an indicator which shows as a white spot at each end of the sign One way signs having one driver board will show a spot at one end only For two way signs with two driver boards the presence of an indication at both ends confirms that both drivers are operating ...

Page 12: ... typical are average values measured across a number of samples and are not guaranteed Lasermet reserve the right to alter any specification without prior notice 7 Warranty Lasermet provide a 12 month warranty for defects in materials and manufacture from the date of installation or delivery Installations completed by Lasermet are covered against defects in workmanship for 12 months Damage or defe...

Page 13: ...o provide a complete system We also supply equipment and consultancy covering all aspects of laser safety Full support design and installation is available from Lasermet please contact us for any queries For sales and technical support Lasermet Ltd Lasermet House 137 Hankinson Road Bournemouth BH9 1HR United Kingdom Tel 44 0 1202 770740 Fax 44 0 1202 770730 Email sales lasermet com Website www las...

Reviews: