![Lasermet ICS-6-OEM Instruction Manual Download Page 29](http://html.mh-extra.com/html/lasermet/ics-6-oem/ics-6-oem_instruction-manual_678396029.webp)
ICS-6-OEM Instruction Manual
01807-53-000
Page 29 of 32
Issue 5 19 January 2021
11
Fuses
The ICS-6-OEM has a number of internal protection fuses which might blow under conditions of fault
or wiring error. In particular the safety loop fuses are usually blown if during wiring the A and B
safety loops are crossed over.
The following fuses are located inside the top of the unit. To access them, the front panel of the ICS-
6-OEM must be removed. Insert the blade of a 3mm flat screwdriver into the rectangular slot at the
ends of the front panel and carefully prise it off.
F1
Expansion 24V Power
3.15AT 20 X 5mm
F2
A Safety Loop
315mA 20 X 5mm
F3
B Safety Loop
315mA 20 X 5mm
There is also a main 24V power fuse rated at 4A 20 X 5mm which is accessed by removing one of the
terminal covers as shown below.