By default, the mismatch detector is factory set to be enabled in option ‘a’ above. To change the
settings of the Safety Circuit Mismatch Detection the cover of the ICS-6-OEM must be removed to
access the internal configuration links. Insert the blade of a 3mm flat screwdriver into the
rectangular slot at the ends of the front panel and carefully prise it off.
The links are located on the top board as shown on the next page.
To prevent the mismatch detector from being reset by cycling the power i.e. to require the detector
to be reset by a technician, remove link J19 ‘Auto RST’.
Note that when link J19 Auto RST is fitted, the power to the ICS-6-OEM must be turned off for at
least 10 seconds to reset the detector and clear the indication.
The Mismatch Detector is enabled by default. To disable the mismatch detector, close link J18
‘Disable’.
Carefully clip the cover back into place once any adjustments have been made.