ThermoCamera HighSense (Pro)
H
A
In manual settings mode, the temperature
range is no longer set automatically based
on the measured min./max. values but rather
determined on the basis of manual values.
The min/max values last measured are taken as the default setting every time the temperature
range is switched from histogram (HG) to manual (MANUAL). Procedure when measuring in
Manual temperature mode. For quick localisation and inspection of the relevant measuring posi-
tions, view the measured object in Automatic mode and determine the optimum measuring
position in which the min/max temperature range approximately corresponds to the required tem-
perature range. Once the min/max values have stabilised, select Manual mode without changing
position to transfer the current values as a default setting using button (b).
!
In Histogram mode, the colour distribution of
the infrared image is adjusted in the same way
as in Automatic mode. In addition, a statistical analysis
of the temperature distribution in the infrared image
(histogram) stabilises the min.max. values. If the tem-
peratures vary significantly, this stabilises the view from
one image to the next, e.g. when measuring moving
objects
In Automatic mode, the measured temperature
range of the infrared image and the resultant
distribution of the colour spectrum are permanently
set. The colour spectrum of the measured infrared
image is determined by the temperature range and
colour scale. The colour distribution of the infrared
image is automatically and dynamically adjusted in the
bargraph based on the measured min./max. values.
11
Temperatue mode:
Automatic, Manual and Histogram mode
41
EN