23
Quadrum OneTounch / Quadrum OneTounch Green
Y
X
X
X
Y
Y
Y
Y
X
X
Y
Y
X
X
Adjustment mode
Take the alignment of the rotary laser into account when
performing adjustment work. Always adjust all the axes.
X axis adjustment
Activate adjustment mode: Switch on the Quadrum OneTouch.
Press the Y axis plus/minus buttons simultaneously until the X LED
flashes rapidly.
Adjustment: Use the X axis plus/minus buttons to move the laser
from its current position to the height of reference point A2.
Cancel adjustment: Switch the device off.
Save: Press the Y axis plus/minus buttons simultaneously until
the X LED comes on.
Y axis adjustment
Activate adjustment mode: Switch on the Quadrum OneTouch.
Press the X axis plus/minus buttons simultaneously until the Y LED
flashes rapidly.
Adjustment: Use the Y axis plus/minus buttons to move the laser
from its current position to the height of reference point A2.
Cancel adjustment: Switch the device off.
Cancel adjustment: Switch the device off. Save: Press the X axis
plus/minus buttons simultaneously until the Y LED comes on.
X- / Y-
Axis
Regularly check the adjustment
before use, after transport and after
extended periods of storage. Always
make sure to control all axes.
!
GB
Manual_QuadrumOneTouch_Rev.0211_DE_NO.indd 23
10.03.11 08:59