MultiMeter-Pocket
GB
15
Diode test
6
To test the diode, turn the rotary switch
to position „
ą
“ and press the „Mode“
switch once to activate the „Diode test“
function. Then connect the measuring
contacts to the diode. The measured
value acquired appears on the display. If
„O.L.“ appears on the display instead of a
measured value, the diode has either been
tested in the reverse direction or is faulty.
Current measurement DC/AC
7
To take a current measurement in the
range from 0 to 200 mA, turn the rotary
switch to position „mA“ and press the
„Mode“ button to set the voltage mode
(AC, DC). To take a current measurement
in the range from 0 to 200
A, turn the
rotary switch to position „
A“ and press
the „Mode“ button to set the voltage
mode (AC, DC). Disconnect the circuit be-
fore connecting the meter. Then connect
the measuring contacts to the object to
be tested. The measured value acquired
and the polarity appear on the display.
Disconnect the circuit again before
disconnecting the meter.
No currents above 200 mA may be measured in the
A/mA
range! Currents above this level trigger the automatic fuse in
the meter.
!
Reverse direction
Forward direction
Forward direction
red
black
red
black
Manual_MultiMeter_Pocket_Rev.0610_GB.indd 15
Manual_MultiMeter_Pocket_Rev.0610_GB.indd 15
05.08.2010 14:35:35 Uhr
05.08.2010 14:35:35 Uhr