MasterLevel Box
09
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning
agents, scouring agents and solvents. Remove the battery(ies) before
storing for longer periods. Store the device in a clean and dry place.
Calibration
The meter needs to be calibrated and tested on a regular basis to
ensure it produces accurate measurement results. We recommend
carrying out calibration once a year.
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be
collected separately for disposal according to
the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=malebo
Technical data
Electronic
measuring precision
± 0,2° at 0° … 90°
Display accuracy
1 decimal place
Operating conditions
0 ... 50°C, 85%rH,
no condensation,
max. altitude 2000 m
Storage conditions
-20 ... 70°C, 85%rH,
no condensation
Power supply
1 x 1.5V (type AAA/LR03)
Dimensions (W x H x D)
59 x 59 x 28 mm
Weight (incl. battery)
86 g
Subject to technical change without notice. 09.17