08
ZERO
HOLD
MasterLevel Box
MasterLevel Box
ZERO
HOLD
MasterLevel Box
ZERO
HOLD
MasterLevel Box
ZERO
HOLD
MasterLevel Box
ZERO
HOLD
MasterLevel Box
ZERO
HOLD
Rev
.1216
MasterLevel Box
A quality product from
GmbH & Co. KG
Donnerfeld 2, 59757 Arnsberg,
Germany, Tel.: +49 2932 638-300,
Fax -333, www.laserliner.com
1.
ABS mode
3.
Relative measuring
mode
2.
ABS mode
1. Place the measuring face (17) on an even surface
with position mark. Switch on device (3). To access
calibration mode simultaneously press buttons 3
and 8. -1- appears on the display.
2. Press the ON/OFF button (3) again. -1- flashes.
The display then changes to -2-.
3. Turn the spirit level by 180° and place it exactly
on the marked surface. Now press the ON/OFF
button (3). -2- flashes. Calibration is concluded
when the measured value appears on the display.
4.
Relative measuring
mode
5.
ABS mode
Press the HOLD button (9) to hold the current measured value on
the display.
Auto Off function
In order to preserve the battery, the measuring device switches off
automatically if it is left idle for 5 minutes.
Error code
– – – –
Alignment of the vertical axis is outside the tolerance range
Calibration
3
Reference function to transfer angles
4
HOLD
5