17
ThermoControl Duo
Subject to technical changes without notice. 20W09
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be collected
separately for disposal according to the European
Directive on waste electrical and electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=AGQ
Technical Data
Precision / Measuring range
± 1°C (0°C … 100°C)
± 2°C (-20°C … 0°C / 100°C … 150°C)
± 3°C (-50°C … -20°C / 150°C … 200°C)
± 5°C (200°C … 300°C)
Operating conditions
0°C … 50°C, max. humidity 80% rH,
no condensation, max. working altitude
2000 m above sea level
Storage conditions
-10°C … 70°C,
max. humidity 80% rH
Radio module
operating data
Bluetooth LE 4.x interface; Frequency band:
ISM band 2400–2483.5 MHz,
40 channels; Transmission power:
max. 10 mW; Bandwidth: 2 MHz;
Bit rate: 1 Mbit/s; Modulation: GFSK/FHSS
Power supply
1 x 3V CR2032
Operating time
150 h
Dimensions (W x H x D)
135 x 40 x 80 mm
Sensor
90 mm, ø 2,5 / 4 mm
Weight
145 g (incl. battery)