OPERATING MODE OF THE ALARM OUTPUTS
The system , in arming active the acoustic signaling (if programmed),the direction indicator of
the vehicle (if programmed) and activate a status output constantly in armed
In alarm phase:
POSITIVE OUTPUTS DIRECTION INDICATOR:
ifif programmed this outputs indicate with the
flash of direction indicator the arming and disarming of the product, and the condition of alarm with a
constant flash for all 30 seconds of the alarm cycle.
OTHERS SETTINGS OF DIRECTION INDICATOR (POSITIVE OUTPUTS SIGNAL)
POSITIVE SIGNAL IN ALARM
This settings allow to signal with a positive signal of 30 seconds the condition of the alarm
POSITIVE SIGNAL WITH PRODUCT IN ARMING
This settings allow to provide with a positive signal the condition of armed status of the alarm that
deactivate at the opened of the vehicle
POSITIVE SIGNAL WITH THE VEHICLE ON (IGNITION KEY ON)
This settings allow to provide with a positive signal , if detected the ignition key code from CAN-BUS
or LIN
POSITIVE SIGNAL WITH REVERSE INSERTED
This settings allow to provide with a positive signal with reverse gear inserted,if detected the code
from CAN-BUS or LIN
POSITIVE SIGNAL AT SPEED LOWER THAN 15 KM / H
This setting allows to supply with a constant positive signal until the vehicle does not exceed 15 Km /
h; the output is reactivated when the vehicle slows below the threshold. If the codes are present
on the CAN-BUS or LIN data
NEGATIVE OUTPUT WITH PRODUCT ARMED:
If programmed, these outputs indicate with a
constant negative signal that the product is armed, they are switched off when the product is
disarmed.
NEGATIVE OUTPUTS DURING ALARM CYCLE:
If programmed these outputs indicate with
a negative signal of 30 seconds that product is alarm condition
NEGATIVE OUTPUTS FOR HAZARD COMMAND:
If programmed and connected to hazard
button of direction indicator, indicating with a negative signal of 25 seconds a condition of alarm
making flashing the direction indicators
TIMED NEGATIVE SIGNAL AT PRODUCT ARMED
This setting allows to provide a timed negative signal programmable from 10 to 45 seconds, at
arming of the product
OTHERS POSSIBLE SETTINGS:
NEGATIVE SIGNAL WITH HANDBRAKE ACTIVETED
This setting allow to provide a negative signal when the handbrake is activated if are detected from
network data of the vehicle
INTERMITTENT NEGATIVE OUTPUT DURING THE ALARM CYCLE (HORN):
If
programmed, this output indicates the 30 second alarm cycle with an intermittent negative
signal. (0.5 sec on and 0.5 sec off interval).
NEGATIVE TIMED SIGNAL FROM VEHICLE DATA LINE
This setting allow to provide with a negative timed signal at the presence of the code detected from