background image

ENGLISH

16

DIP SWITCH CODING TABLE

TECHNICAL DATA

POWER SUPPLY: ............................................................................................... 12V DC

CURRENT DRAW WITH ALARM ON (989-989EES-988): ..................................... 23  mA

CURRENT DRAW WITH ALARM ON (975-974): ................................................... 16  mA

CURRENT DRAW WITH ALARM OFF (989-989EES-988):..................................... 13 mA

CURRENT DRAW WITH ALARM OFF (975-974): .................................................. 13  mA

EXIT DELAY: ................................................................................................. 40 seconds

MAX. ALARM CYCLE DURATION: ................................................................. 30  seconds

TIME BETWEEN CONSECUTIVE ALARMS ....................................................... 5   seconds

ULTRASONIC SENSOR FREQUENCY:................................................................. 40 Khz

MAX. BLINKER RELAY CONTACT CAPACITY...............................................5+5 Ampere

MAX. STOP ENGINE RELAY CONTACTS CAPACITY: .......................................8 Ampere

989 range of products meets the requirements of the EEC 95/54 directive

concerning the Electromagnetic Compatibility (EMC) and the EEC 95/56 directive

concerning protection device against unauthorised use of motorvehicle and ETS

norms applied in this case

Dip-switch n° Position Function

1

OFF

ON

AUTO-CODE FUNCTION 

DEACTIVATED

AUTO-CODE FUNCTION 

ACTIVATED

2

OFF

ON

VOLT DROP SENSING 

ACTIVATE

VOLT DROP SENSING 

DEACTIVATED

3

OFF

ON

ACOUSTIC TONE 

ACTIVATED

ACOUSTIC TONE 

DEACTIVATED

4

OFF

ON

CASUAL RE-ARMING AND AUTOMATIC STOP ENGINE  

ACTIVATED

CASUAL RE-ARMING AND AUTOMATIC STOP ENGINE  

DEACTIVATED

5

OFF

ON

CLOSURE FUNCTION 

(COMFORT CLOSING time 1”)

CLOSURE FUNCTION 

(COMFORT CLOSING ONLY time 25”)

6

OFF

ON

ELECTRIC CENTRAL LOCKING 

(pulse time 1 sec.)

PNEUMATIC CENTRAL LOCKING 

(pulse time 2 sec.)

is 989E ita-ing.pm6

05/03/98, 16.42

16

Summary of Contents for 974E

Page 1: ...ENGLISH 11 FITTING INSTRUCTION COMPACT ALARM CAR ALARMS SYSTEMS 989E 988E 989EES with siren exclusion 975E 974E without ultrasonic is 989E ita ing pm6 05 03 98 16 42 11...

Page 2: ...OTICE Route wires as far as possible from interference sources high tension coil spark plug wires Fix ultrasonic sensors AT THE TOP of the right and left A pillars as far as possible from ventilation...

Page 3: ...esn t happen increase the sensitivity and repeat the test Do not set too high as false alarm may result clockwise maximum sensitivity anti clockwise minimum sensitivity anti clockwise until the end se...

Page 4: ...he same detector ULTRA SONICS SENSOR PUSH BUTTONS after the third cicle of siren sound that detector is excluded but it is not possible to start car engine SECURITY KEY inOFFpositionitexcludesalltheal...

Page 5: ...position 3 Open bonnet and remove access plate on rear of siren 4 Move DIP switch No 1 to ON position The LED on the dashboard will now light on constantly 5 Within 30 seconds of constant LED illumina...

Page 6: ...e concerning the Electromagnetic Compatibility EMC and the EEC 95 56 directive concerning protection device against unauthorised use of motorvehicle and ETS norms applied in this case Dip switch n Pos...

Page 7: ...O NOT LEAVE DISCONNECTED THIS WIRE SAFETY SWITCH POSITIVE OUTPUT DURING THE ALARM 3 A max 12V WINDOWS CLOSER ART 824 811 828 POSITIVE BATTERY HAZARD BROWN YELLOW YELLOW CENTRALLOCKING BLUE AERIAL WHIT...

Page 8: ...BLACK AND RED BLACK WIRES DIP SWITCH NO 6 OFF 1 SECOND PULSE DIP SWITCH NO 6 ON 3 SECONDS PULSE DIP SWITCH NO 5 ON 25 SECONDS PULSE lock only DO NOT USE LIGHT BLUE BLACK AND RED BLACK WIRES DIAGRAM 2...

Page 9: ...CTIONS CUT DOOR PUMP GREEN BLACK GREY BLACK BROW BLACK YELLOW BLACK ALARM SYSTEM BLUE BLACK RED BLACK LINK POSITIVE 12V GROUND DIP SWITCH NO 6 ON 3 SECONDS DIP SWITCH NO 5 OFF 3 SECONDS DIP SWITCH NO...

Page 10: ...connect to ground GREEN BLACK YELLOW BLACK connect to a fused positive supply GREY BLACK connect to the blue wire of the central locking motor BROWN BLACK connect to the red wire of the central lockin...