Page 16 - Laser Technology, Inc. LTI 20/20 TruSpeed Metric User’s Manual 3rd Edition
Copyright (c)[2013] Laser Technology, Inc. All rights reserved. Unauthorized duplication, in whole or in part, is strictly prohibited
Error Codes
**See inside front cover for LTI contact information.
RFI Considerations
The TruSpeed does not display a specific error message indicating the presence
of radio frequency interference (RFI). The instrument's electronics have been
designed for optimum RFI immunity. If RFI is present, the instrument displays an
error code. The exact code depends on the level and nature of the RFI.
Code
Explanation
E 01
Measurement Error: The target was out of the instrument’s measurement
range. Note: If the target distance is less than the instrument’s minimum
speed measurement range, the target distance will be displayed along with
the E01 error code.
E 03
Measurement Error: Unstable targeting. Data is not stable enough to
measure speed.
Possible Causes: poor aiming or panning off the target.
E 03
E 07
Measurement Error: Low level of interference from a light source such as a
xenon headlight.
Jam Detect. High level of interference from a light source such as a xenon
headlight.
E 52
Temperature too cold. Stop operation.
E 53
Temperature too hot. Stop operation.
E 54
Low Battery.
E 55 E57
E 56 E58
Calibration Errors. Please turn OFF unit and try again. If the same error is
continuously repeated, please contact LTI. **
E 59
Receive circuit calibration failure. Please turn OFF unit and try again. If the
same error is continuously repeated, please contact LTI. **
E 60
Memory failure. Please turn OFF unit and try again. If the same error is
continuously repeated, please contact LTI. **
E 62
Receiver Failure. Please turn OFF unit and try again. If the same error is
continuously repeated, please contact LTI. **
E 63 E65
E 64 E66
E 67
Code Checksum Failure. Please turn OFF unit and try again.
If the same error is continuously repeated, please contact LTI.**
E 68
Power Supply High Voltage Failure. Please turn OFF unit and try again. If
the same error is continuously repeated, please contact LTI. **
E 71
System Error. Please turn OFF unit and try again. If the same error is
continuously repeated, please contact LTI. **
E 99
General System Failure. Please contact LTI. **