L’ARTISTICO SRL |
EN
29
Cod. 40580 | Rev. 01 | 04/2021
ATTENTION: In Italy, the wall flue exhaust is
strictly prohibited by all national, regional and local
laws.
In some European countries, wall flue gas discharge
is allowed. Below are three diagrams for wall flue exhaust in
the countries where it is allowed.
17. CROSSING ROOFS/CEILING INFLAMMABLES
Be very careful when getting through walls, ceilings or roofs made of
flammable materials. The high smoke temperatures can start a fire.
Do always respect the safety distances as per UNI 10683 Italian
regulation. For all other countries, respect all local and national
regulations in force.
A = isolated double-walled tube
B = flammable material
X = The distance indicated on the chimney plate GXXX in mm
18. PELLET EXTRACTION AND LOADING
The extraction of the insert allows both to load the pellets inside the
tank and to perform routine maintenance (cleaning the flue gas duct at
the end of the year) or extraordinary (replacement of mechanical parts
in case of breakage).
WARNING: the insert must be extracted only with
the machine turned off and completely cold. Surfaces
can get very hot.
To extract the insert, perform the following procedure:
1)
Open the door. To release the insert body from the frame, use
the lock / release lever with a lateral movement. The lever has
a spring system: push it to the left both to unlock and extract
the insert, and to lock and close. It is advisable to use the
handle supplied as standard to help with the operation.
M
IN
1
,5
m
e
tr
i
M
IN
2
m
e
tr
i
Inclinaison > 3%
Longueur < 3 m
Fig. 21
Fig. 22
Fig. 23
ISOLATION