CHAPTER 4
COMMUNICATION PROTOCOLS
4-3
DC-24 and DC-25 operation manual
Example: Data sent to the address 04. Temperature 18.6°C and relative humidity 47%.
Header
Address
Code
Temp
Space
Hum
End of block
Characters
@
1 5
V T
18,6
47
Carry return
Decimal
64d
49d 53d
86d 84d
49d 56d 44d 54d
32d
52d 55d
13d
Hexadecimal
40h
31h 35h
56h 54h
31h 38h 2Ch 36h
20h
34h 37h
0Dh
Response from the display
The response message from the display is the following:
Header
Address
Code
End of block
Characters
@
High Low
V T
Carry return
Decimal
64d
86d 84d
13d
Hexadecimal
40h
56h 54h
0Dh
The address returned is the one of the display
Example: Frame returned when data has been sent
Header
Address
Code
End of block
Characters
@
0 4
V T
Carry return
Decimal
64d
48d 52d
86d 84d
13d
Hexadecimal
40h
30h 34h
56h 54h
0Dh