OPERATION
1.
Use the handle on the back of the light to tilt up/down and pan left/right.
2.
Adjust the tightness of pivot/pan movement using the tightening bolts on the
side of the base hinge.
3.
Connect the Deutsch connector from power cord to light.
4.
Connect power source and flip the switch on back of light to turn on.
NOTE:
Check for proper voltage before first use!
5.
Power transformers (DCP-11-DP) can be purchased through our website to run
this spotlight from household wall
outlets.
The sealed beam in this unit pulls 13 amps continuously, so 15 amp fuse is required. A 15 amp fuse is typical
on most cigarette lighter sockets, however, it is not recommended that you attempt to run 2 of these lights on a
socket splitter without increasing the fuse capacity.
This spotlight produces 1050 LUX at 25 feet, and projects a beam
700 feet. At its widest point, the beam is nearly 70 feet wide. The light is designed to project light at distance and the
beam pattern resembles a long cigar with its thickest point past the midway point.
MOUNTING
The light features a permanent mount base, measuring 4 inches square that is secured with 4 corner bolts. Mount
light securely; making sure bracket is square with surface.
ADJUST LIGHT
Light beam can be adjusted vertically/horizontally by the handle. The spotlight, will hold its position once the beam is
placed. Adjust the tightening bolt to increase or lessen the "position holding" tension based on the amount of vibration in
the environment. Should light adjustment become loose, tighten bolts on the base.
To change the lamp
, remove the scre
ws
on the
lens cover
. Take the face ring off of the lamp
and pull the bulb out of the socket freeing it form the spring fasteners. Place the new bulb in its
socket and replace face ring.
Lens Screw
MAINTENANCE
I
is good practice to routinely clean and check the fixture for proper function.
•
Disconnect power running to the lamp and be sure the fixture is cool to the touch.
•
Use a non-abrasive glass cleaning solution to clean the lens.
USE AND CARE
Unauthorized modification may impair the function and/or safety of this device and could affect the life of the equipment.
Always check for damaged or worn out parts before using the device. Store it in a secure place out of the reach of
children when not in use. Inspect for good working condition prior to storage and before re-use.
REPLACEMENT PARTS
The
PML-15
is designed to provide years of reliable performance. Should the need for replacement parts arise, please
contact Larson Electronics.
THESE INSTRUCTIONS MAY NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS.
SHOULD FURTHER INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL AT
OR BY PHONE AT 1-800-369-6671 FOR FURTHER ASSISTANCE.
PLEASE VISIT LARSONELECTRONICS.COM FOR
WARRANTY
AND
RETURN
INFORMATION.