Motion Sensor

7A Max Load - Low Power Draw - Add to Existing Fixtures - Adjustable Time & 

Range

Instruction Manual

Thank you for your purchase of the Larson Electronics

 MS-AT-7A-LV

.

WARNING: 

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. 

CRITICAL SAFETY INSTRUCTIONS: 

INSTALLATION SHOULD ONLY BE CONDUCTED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NEC AND ANY

RELEVANT LOCAL BUILDING CODES.

RISK OF FIRE OR ELECTRIC SHOCK. FIXTURE INSTALLATION REQUIRES KNOWLEDGE OF 

FIXTURE'S

 ELECTRICAL

SYSTEMS. IF NOT QUALIFIED, CONTACT A QUALIFIED ELECTRICIAN.

BE CERTAIN ELECTRICAL POWER IS OFF BEFORE AND DURING INSTALLATION AND MAINTENANCE.

MAKE SURE THE SUPPLY VOLTAGE IS THE SAME AS THE

 FIXTURE'S

 RATED VOLTAGE.

TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR SHARP

OBJECTS. SUITABLE FOR DAMP LOCATIONS.

IMPORTANT

 

READ CAREFULLY BEFORE INSTALLING THIS FIXTURE. SAVE THESE INSTRUCTIONS FOR FUTURE 

REFERENCE. THE 

MS-AT-7A-LV

  MUST BE WIRED IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND 

ALL APPLICABLE LOCAL CODES. PROPER GROUNDING IS REQUIRED FOR SAFETY.  

WE STRONGLY ENCOURAGE ONLY A LICENSED ELECTRICIAN INSTALL, OPERATE AND MAINTAIN THIS 

PRODUCT. IF YOU ARE NOT QUALIFIED OR UNFAMILIAR WITH ANY ASPECT  OF THIS INSTRUCTION SHEET, 

CONSULT AN ELECTRICIAN. THERE ARE NO SERVICEABLE PARTS INSIDE. 

WARNING:

 

MAKE SURE POWER IS TURNED 

OFF

 BEFORE STARTING THE 

INSTALLATION OR PERFORMING ANY MAINTENANCE.

 

 

RISK OF FIRE/ELECTRIC SHOCK –

 

DISCONNECT POWER AT BREAKER BEFORE INSTALLING OR SERVICING.

 

RISK OF PERSONAL INJURY –

 

FIXTURE MAY BECOME UNSTABLE OR DAMAGED IF NOT INSTALLED PROPERLY. 

RISK OF BURN –

 

ALLOW FIXTURE TO COOL BEFORE SERVICING. 

The MS-AT-7A-LV from Larson Electronics is a Motion Sensor that allows operators to add motion sensing functionality to 

existing fixtures. This motion sensor can operate on either 12V DC or 24V DC and has a max amp load of 7 amps while 

only consuming approximately 0.5 watts of power.

Low Voltage DC 

Connect power to power supply outputting low voltage between 

12-24

  Volts  DC. 

This variable voltage allows greater versatility without affecting light output. Ensure 

deutsch connectors are properly connected (If applicable)

.

 

INSTALLATION

Avoid installing where there is sunshine or constant air stream and temperature changes. Connect the lines according to 

the right configuration. Wires are labeled according to input and output leads.

Use Only Low Voltage 12/24V DC for 

both IN/OUT.

Mount motion sensor using the mounting ears on either side of the enclosure box. Plan a way for routing wires.

DC IN= POWER SUPPLY

DC LOAD= LIGHT (DEVICE TO BE POWERED)

DIP SWITCHES

DIP SWITCH ACCESS UNDER FRONT COVER

SENS

TIME

LUX

1 2

2M (6.6FT)
4M (13FT)
6M (20FT)
8M (26FT)

10S
1Min
5Min

10Min

15Min
20Min
25Min
30Min

24H
10Lux

20Lux

50Lux

100Lux
200Lux

300Lux

500Lux

3 4 5

6 7 8

3 4 5

7 8

ON

6