Larson Electronics, LLC
Phone: (800) 369-6671
Fax: (903) 498-3364
www.larsonelectronics.com
7
of
1
3
IND-MD-TF-MGF-HH-R1
5
.
Notes in operation of the machine:
5-1, If the oil bubble is pressed too many times in case there is oil in the bubble, which leads to too much oil in
the carburetor, you need to bring the machine with the nozzle downwards to poured out the extra petrol. Then the
machine can be started directly without pressing the oil bubble.
5-2, In the shutdown, if the solution valve is closed after the machine is accidentally turned off, it will cause the
solution return to the machine, and the machine does not work. In this case, do not immediately start the machine again,
otherwise the machine will be damaged due to short circuit of the high-voltage bag. Bring the machine with the nozzle
downwards to poured out the extra petrol. And then start the machine.
5-3, When the outside temperatl:lre is too low, the machine will power off instantaneously. In this case, you need
to long press the start button after the machine is started, and open the selution valve meanwhile until the machine
works normally.
6. Notes
1 , The machine is strictly prohibited to be used in flammable and explosive places.
2, The machine uses gasoline as fuel,
attention should be paid to fire fighting. Ignition and smoking is strictly prohibited
near the machine.
3, It is strictly prohibited to open the carburetor to check igniter ignition.
4, The oil tank cover should be tightened after the oil is filled, the leakage of fuel should be cleaned, and the machine
should be started far away from the refueling site.
5, It is prohibited to fill or dump the oil when the machine is in operation or just stopped.
6, In operation, the high temperature parts can not touch people or animals, to avoid accidental injury, see figure 2.
Forcibly cooling with water after the machine is stopped is strictly prohibited, which can seriously damage the machine.
7, For the health of operators, when working in the field, the operator should stand in the uptake of the nozzle to operate,
and should not walk along the direction of the wind. When working indoors, the operator should spray from the inside to
the outside. When the ope
r
ator comes to the door, he stops the machine, and closes the door after coming out from
the room to ensure the personal safety and effective killing of the insect or virus.
8, It is prohibited to use electric arc or acetylene welding method for welding or cutting on the machine with pesticides
or gasoline residues. When the oil tank or pesticide solution tank leaks, please contact the dealer or professional after-
sales service personnel to handle.
9, When the residual pesticides or washing liquid of the pesticide tank is handled, please follow the safety instructions
provided by the pesticides manufacturer. 10, After the machine completes its work, please close the pesticide solution
valve and then turn off the engine, or do both actions at the same time; if the engine unexpectedly flameout, please
close the valve quickly.
11, Empty the fuel inside the oil tank and carburretter before the machine is stored. For products of electrical
series, the pesticide tank and pump shall be Gleaned with clean water, and the machine shall be cleaned also, then
place the machine in ventilated place away from fire. For long time storing, the machine should be charged every 30
days and each time for 5 hours.
12, The machine should be placed in a place away from children, to avoid accidents.
13, The operator must wear labour protection appliance according to the following requirements. (see Figure 3):