background image

 IND-HVAC-DTW-UVC-R1-SS series

        Overexposure to germicidal ultraviolet rays will result in the irritation of the 

eyes and reddening of the skin. For this reason, it is of the utmost importance that your 

ultraviolet application be carefully planned and implemented so as to avoid exposure,of 

personnel, to direct or reflected ultraviolet rays.

CAUTION

!

The American Conference of Governmental Industrial Hygienists (ACGIH) has established a Threshold Limit Value (TLV)

 

for

occupational exposure to radiant ultraviolet energy.

Currently the ultraviolet radiant exposure incident for unprotected eyes or skin should not exceed 0.2 microwatts per square

centimeter (µW/cm2) at 254 nanometers (nm) for an eight (8) hour period.

Safety and maintenance procedures 

MUST

 be implemented to prevent accidental exposure of personnel, who maintain the

HVAC system. All work performed on the HVAC system must be monitored to ensure that it does not adversely impact the

safety or effectiveness of the installation.

UNPACKING

IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY 

EQUIPMENT: SAFETY  GLASSES OR A FACE SHIELD, AS WELL AS GLOVES.

Remove the Air Duct Disinfection Unit from its shipping carton.

Larson Electronics takes all possible precautions when packaging this unit to prevent damage. Carefully inspect the

 

unit,

 and

 power cord for damage and report all damage immediately. Do not assemble or operate if there is any

 

damage, visible or suspected.

Germicidal lamps are packed separately, to ensure maximum protection for the lamps. Keep the lamps aside until

 

ready for installation.

Do not discard packing materials until unit is assembled and start up is complete.

The

 

 

single 

unit includes: 

1 - Single lamp

 

unit with line cord

1 -  Germicidal Ultraviolet Lamp

1 - Operating Instructions

Larson Electronics, LLC

 

 Phone: (800) 369-6671 

 Fax: (903) 498-3364 

 www.larsonelectronics.com 

4

 of 

10

 

The 2 unit includes: 

1 - 2 lamp

  

unit with line cord

2 - Germicidal Ultraviolet Lamps

1 - Operating Instructions

The 4 unit includes: 

1 - 4 lamp unit with line cord

4 - 

  

Germicidal Ultraviolet Lamps

1 - Operating Instructions

Summary of Contents for IND-HVAC-DTW-UVC-R1-SS Series

Page 1: ...ons when packaging equipment to prevent damage Carefully inspect and report all damages Do not install damaged equipment Follow all instructions on any labels or tags Carefully inspect all packing mat...

Page 2: ...pictorial is used to identify components which must not be disposed of in trash SAFETY INSTRUCTIONS To guard against injury basic safety precautions should be observed including the following 1 Read...

Page 3: ...harsh environments PRINCIPLE OF OPERATION The design has been carefully conceived to provide adequate germicidal ultraviolet dosage for air stream or surface disinfection in new or existing HVAC Heati...

Page 4: ...the safety or effectiveness of the installation UNPACKING IN ORDER TO PERFORM THIS TASK BE SURE TO WEAR THE FOLLOWING SAFETY EQUIPMENT SAFETY GLASSES OR A FACE SHIELD AS WELL AS GLOVES Remove the Air...

Page 5: ...ssary seal all openings joints seams etc using aluminum tape or equivalent ultraviolet resistant material Prevent exposure of any plastic rubber or other non metallic materials with inadequate resista...

Page 6: ...Outside Duct Mount Opening for outside mount shown Insert unit Attach unit using the face mounting bracket and self drilling screws View inside duct INSTALLATION Larson Electronics LLC Phone 800 369...

Page 7: ...ly seated 8 Repeat until all lamps have been properly installed 9 Moisten a clean lint free cloth with denatured alcohol and wipe each lamp 10 Clean the outer surface of duct around cutouts 11 Fit the...

Page 8: ...t our Application Specialists MAINTENANCE Always disconnect power to the unit before performing any service or maintenance WARNING The Air Duct Disinfection Unit is designed to operate with a minimal...

Page 9: ...censed personnel Table 1 Troubleshooting Problem Possible Cause Corrective Action Unit not operating No electrical power Verify that the unit is connected to a live power source Power connection to fi...

Page 10: ...ht without adequate eye protection Make it a policy to never enter areas being disinfected with UV lighting systems without powering the system down first Methods of powering down depends on the optio...

Reviews: