background image

HAL-16C-185LED-CPR-100

Larson Electronics, LLC

 

  Phone: (800) 369-6671 

 Fax: (903) 498-3364 

  www.larsonelectronics.com 

2

 of 

2

 

WIRING 

(see attached wiring diagram)

 

This unit comes preconfigured with selected cord cap.

 The is outfitted with 100` of 16/3 chemical and abrasion 

resistant SOOW cord that is fitted with an explosion proof cord cap for easy connection to explosion proof 

outlets. Plug options include a 5-15 15 amp straight blade plug for use with 120V explosion proof outlets, a 5-20 

20 amp straight blade plug for use with 120V explosion proof outlets, or a 6-20 20 amp straight blade plug for 

use with 220-240V explosion proof outlets. **PLEASE NOTE** voltage ratings on plugs and outlets are 

MAXIMUM voltage. For low voltage applications, proper voltage must be applied to the outlet or damage to the 

light fixture will occur.

MAINTENANCE

 

Caution: 

To avoid personal injury, disconnect power to the light and allow the unit to cool down before 

performing maintenance. 

Warning: 

No user serviceable parts inside of fixture. Risk of electric shock. Removal of the lens will void 

the warranty. 

1.

Perform visual, mechanical and electrical inspections on a regular basis. We recommend routine
checks to be made on a yearly basis. Frequency of use and environment should determine this.  It is
recommended to follow an Electrical Preventive Maintenance Program as described in NFPA 70B:
Recommended practice for Electrical Equipment.

2.

The lens should be cleaned periodically as needed to ensure continued photometric performance.
Clean the lens with a damp, non-abrasive, lint-free cloth. If not sufficient, use mild soap or a liquid
cleaner.

3.

Inspect the cooking fins on the luminaire to ensure that they are free of any obstructions or
contamination (i.e. excessive dust build-up). Clean with a non-abrasive cloth if needed.

4.

Do not operate if the lens is cracked or damaged. All fasteners should be properly seated.

WARRANTY 

Should further information not covered by these instructions be required, please contact Larson Electronics at 
1-800-369-6671 or [email protected] for further assistance.

Please visit LarsonElectronics.com for 

Warranty

 and 

Return

 information.

WARNING:

 CHECK NAMEPLATE 

FOR PROPER VOLTAGE. DAMAGE 
FROM IMPROPER VOLTAGE MAY 
VOID WARRANTY.