![background image](http://html1.mh-extra.com/html/larson-electronics/gvp-48-2l-led-48vdc-r2/gvp-48-2l-led-48vdc-r2_instruction-manual_3842963002.webp)
GVP-48-2L-LED-48VDC-R2
Larson Electronics, LLC
Phone: (800) 369-6671
Fax: (903) 498-3364
www.larsonelectronics.com
2
of
3
SAFETY INSTRUCTIONS (Read Carefully for your Protection)
•
ETL listed for indoor use only.
•
Connect fixture to voltage on nameplate. Universal voltage 120-277VAC 50/60 Hz or 11-25V AC/DC depending
on model purchased.
•
A qualified electrician or person with experience in household wiring should install this fixture. The electrical
system and the method of connecting to electricity must be in accordance with the National Electrical Code and
local building codes.
•
Keep away from flammable objects. Do not position fixture within one inch of any combustible materials.
•
Your light fixture is prewired for easy installation.
•
This fixture is rated for 50,000+ hours.
•
Wear rubber sole shoes and work on a sturdy wooden ladder.
•
To avoid hazard to children, account for all parts and destroy packing materials.
PREPARATION
•
Before beginning assembly, installation, or operation of product, make sure all parts are present.
Compare parts with the package contents list and diagram.
•
If any part is missing or damaged, do not attempt to assemble, install or operate the product.
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
Light does not come on
No power to the fixture
Check if circuit breaker is tripped
Wiring to the unit is loose
---
Confirm fixture is properly grounded
QUESTIONS, PROBLEMS, MISSING PARTS
Before returning your fixture, please call Larson Electronics at 1-800-369-6671 or log on to
http://www.larsonelectronics.com for replacement parts.
WARNING
•
Always hire a licensed electrician for proper installation.
•
Always mount this fixture to a grounded junction/breaker box.
LIGHT ASSEMBLY
1.
Turn off the power at the main fuse or breaker box.
2.
Remove clips and open fixture.
3.
Turn latches 90° to release lamp holder board.
4.
Thread wires through wire gland and back cover wire hole.
Connect the wires to the wire terminal L to L, N to N then fasten the wire gland.
6.
Put the lamp holder board in the back cover, fixing poles through the board’s holes. Then turn the head of
latches 90° to fix the board to back cover.
7.
Install lamp.
8.
Use the lens and back cover clips to attach lens to back cover.
9.
Use the wall clips to attach light fixture to wall.
10.
Turn power on at main fuse breaker box.
MAINTENANCE
Caution:
To avoid personal injury, disconnect power to the light and allow the unit to cool down before performing maintenance.
Warning:
No user serviceable parts inside of fixture. Risk of electric shock. Removal of the lens will void the warranty.
1.
Perform visual, mechanical and electrical inspections on a regular basis. We recommend routine
checks to be made on a
yearly basis. Frequency of use and environment should determine this. It is
recommended to follow an Electrical Preventive
Maintenance Program as described in NFPA 70B:
Recommended practice for Electrical Equipment.
2.
The lens should be cleaned periodically as needed to ensure continued photometric performance.
Clean the lens with a damp,
non-abrasive, lint-free cloth. If not sufficient, use mild soap or a liquid
cleaner.
3.
Inspect the cooling fins on the luminaire to ensure that they are free of any obstructions or
contamination (i.e. excessive dust
build-up). Clean with a non-abrasive cloth if needed.
4.
Do not operate if the lens is cracked or damaged. All fasteners should be properly seated.