background image

GAU-LTL-500W-LED-IR

Larson Electronics, LLC

 

 Phone: (800) 369-6671 

Fax: (903) 498-3364 

www.larsonelectronics.com 

2

 of 

2

 

INSTALLATION 

We strongly recommend only a licensed electrician install this product. Make sure 
power is disconnected prior to installing. Fixture must be mounted to a surface that 
can structurally support the load. 

The fixture will be supplied with a cord cap/whip already affixed to the housing. 

Mount following the steps below: 

1.

Turn off power at electrical panel

.

2.

Mount light by its trunnion mount to a flat surface. Utilize bolts

 

through predrilled 

mounting holes.

3.

Adjust lamp vertically by loosening hex bolts on either side.

4.

Swing lamp into final position and tighten any loose bolts.

5.

Wire the whip/power cord to existing power source. Follow proper

 

steps to 

weatherproof electrical connections as necessary.

6.

 

Turn power on.

This light is “instant-on” and will illuminate once power is supplied to the unit.

 

Double check voltage prior to plugging in! 

This light is “instant-on” and will illuminate once power is supplied to the unit. 

Wire Diagrams 

(Match wire colors to unit received.)

THESE  INSTRUCTIONS  MAY  NOT  COVER  ALL  DETAILS  OR  VARIATIONS  OF  THIS  PRODUCT  FOR  YOUR  EQUIPMENT  OR  INSTALLATION  REQUIREMENTS.  SHOULD  FURTHER 
INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL A

[email protected]

 OR BY PHONE 

AT 1-800-369-6671 FOR FURTHER ASSISTANCE. 

PLEASE VISIT LARSONELECTRONICS.COM FOR 

WARRANTY

 AND 

RETURN

 INFORMATION. 

Voltage: 

120-277V AC 

*ACTUAL STYLE MAY VARY

ADJUTMENT BOLTS 

MAINTENANCE 

Caution: 

To avoid personal injury, disconnect power to the light and allow the unit to cool down before performing maintenance. 

Warning: 

No user serviceable parts inside of fixture. Risk of electric shock. Removal of the lens will void the warranty. 

1.

Perform visual, mechanical and electrical inspections on a regular basis. We recommend routine

 

checks to be made on a 

yearly basis. Frequency of use and environment should determine this.  It is

 

recommended to follow an Electrical Preventive 

Maintenance Program as described in NFPA 70B:

 

Recommended practice for Electrical Equipment.

2.

The lens should be cleaned periodically as needed to ensure continued photometric performance.

 

Clean the lens with a 

damp, non-abrasive, lint-free cloth. If not sufficient, use mild soap or a liquid

 

cleaner.

3.

Inspect the cooling fins on the luminaire to ensure that they are free of any obstructions or

 

contamination (i.e. excessive 

dust build-up). Clean with a non-abrasive cloth if needed.

4.

Do not operate if the lens is cracked or damaged. All fasteners should be properly seated.

USE AND CARE

Unauthorized modification may impair the function and/or safety of this device and could affect the life of the equipment. 

Always check for damaged or worn out parts before using the device. Store it in a secure place out of the reach of 

children when not in use. Inspect for good working condition prior to storage and before re-use.

 

 

REPLACEMENT PARTS

The EPP-20A-25P is designed to provide years of reliable performance. Should the need for replacement parts arise, 

please contact Larson Electronics. 