INSTALLATION
We strongly recommend only a licensed electrician install this product. Make sure
power is disconnected prior to installing. Fixture must be mounted to a surface that
can structurally support the load.
The fixture will be supplied with a cord cap/whip already affixed to the housing.
Mount following the steps below:
1.
Turn off power at electrical panel
.
2.
Mount light by its trunnion mount to a flat surface. Utilize bolts
through predrilled
mounting holes.
3.
Adjust lamp vertically by loosening hex bolts on either side.
4.
Swing lamp into final position and tighten any loose bolts.
5.
Wire the whip/power cord to existing power source. Follow proper
steps to
weatherproof electrical connections as necessary.
6.
Turn power on.
This light is “instant-on” and will illuminate once power is supplied to the unit.
Double check voltage prior to plugging in!
This light is “instant-on” and will illuminate once power is supplied to the unit.
Wire Diagrams
(Match wire colors to unit received.)
THESE INSTRUCTIONS MAY NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS. SHOULD FURTHER
INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL AT
OR BY PHONE
AT 1-800-369-6671 FOR FURTHER ASSISTANCE.
PLEASE VISIT LARSONELECTRONICS.COM FOR
WARRANTY
AND
RETURN
INFORMATION.
Voltage:
120-277V AC
*ACTUAL STYLE MAY VARY
ADJUTMENT BOLTS
MAINTENANCE
Caution:
To avoid personal injury, disconnect power to the light and allow the unit to cool down before performing maintenance.
Warning:
No user serviceable parts inside of fixture. Risk of electric shock. Removal of the lens will void the warranty.
1.
Perform visual, mechanical and electrical inspections on a regular basis. We recommend routine
checks to be made on a
yearly basis. Frequency of use and environment should determine this. It is
recommended to follow an Electrical Preventive
Maintenance Program as described in NFPA 70B:
Recommended practice for Electrical Equipment.
2.
The lens should be cleaned periodically as needed to ensure continued photometric performance.
Clean the lens with a
damp, non-abrasive, lint-free cloth. If not sufficient, use mild soap or a liquid
cleaner.
3.
Inspect the cooling fins on the luminaire to ensure that they are free of any obstructions or
contamination (i.e. excessive
dust build-up). Clean with a non-abrasive cloth if needed.
4.
Do not operate if the lens is cracked or damaged. All fasteners should be properly seated.
USE AND CARE
Unauthorized modification may impair the function and/or safety of this device and could affect the life of the equipment.
Always check for damaged or worn out parts before using the device. Store it in a secure place out of the reach of
children when not in use. Inspect for good working condition prior to storage and before re-use.
REPLACEMENT PARTS
The EPP-20A-25P is designed to provide years of reliable performance. Should the need for replacement parts arise,
please contact Larson Electronics.