background image

When the power is turned ON, the red and green LEDs flash for few seconds.

During a detection the red LED lights illuminates.

During configuration, the red LED flashes a number of times corresponding to the parameter being changed (see

next table). The green LED flashes a number corresponding to its setting.

EXP-MS-30W-N4X | Larson Electronics, LLC

Page 

of 

4

POSSIBLE SETTINGS BY REMOTE CONTROL

1-6

-75°
-60°
-45°

Choose the right detection filter for your application with the remote control

Value recommendations according to angle and height:

 

Detection of all targets

(pedestrians and parallel traffic are detected)

1 = no specific filter

2 = filter against disturbances 
      (recommended in case of vibrations, rain etc.) 

Detection only of vehicles moving*

(pedestrians and parallel traffic are not de disturbances are filtered)

* The vehicle detection filter increases the response time of the sensor.

Always check if the chosen 

value is optimal for the appli-
cation.
The object size and nature 

can influence the detection.

23 ft - 11.5 ft    8 ft
        3         
        4         

         5        

DETECTION FILTER 

(REJECTION MODE)

   

     3  

           

     4

                    4

LED SIGNALS

POSSIBLE SETTINGS BY PUSH BUTTONS

(7)
(0)
(1)
(2)
(1)

TO START OR END AN ADJUSTMENT SESSION

, press and hold either push button until the LED flashes or stops 

flashing.

1

  FIELD SIZE

Parameter number

2

  HOLD-OPEN TIME

3

  OUTPUT CONFIGURATION

4

  DETECTION MODE

5

  DETECTION FILTER

Value (factory values)

TO SCROLL THROUGH THE 
PARAMETERS, press 
the right push button.

TO CHANGE THE VALUE 
OF THE CHOSEN 
PARAMETER, press the left 
push button.

TO RESET TO FACTORY VALUES

, press and hold both push buttons until both LEDs flash.

FIELD SIZE

OUTPUT
CONFIGURATION

DETECTION MODE

FACTORY VALUES

RESETTING TO FACTORY VALUES:

DETECTION FILTER

RELAY HOLD TIME

XXS

XS

S

>

>

>

>

L

XL

XXL

0.5 s

1 s

2 s

3 s

4 s

5 s

6 s

7 s

8 s

9 s

3

4

5

6

1

2

P

A

A = active output 

(relay active when detection)

P = passive output 

(relay active when no detection)

uni

AWAY

bi = two-way detection

uni = one-way detection towards sensor

uni AWAY = one-way detection away from sensor

bi

uni

CHECKING A VALUE

Red

Red

X

Green

Off

X = number of flashes = value of parameter

Reviews: