Explosion Proof LED Paint Spray Booth Light 

3rd Gen - Class 1 Div 1 - Class 2 Div 1 

Instruction Manual 

Thank you for your purchase of the Larson Electronics

 EPLRL-50-16.4-HR-SWB

.

WARNING: 

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. 

CRITICAL SAFETY INSTRUCTIONS: 

INSTALLATION SHOULD ONLY BE CONDUCTED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NEC AND ANY

RELEVANT LOCAL BUILDING CODES.

RISK OF FIRE OR ELECTRIC SHOCK. FIXTURE INSTALLATION REQUIRES KNOWLEDGE OF 

FIXTURE'S

 ELECTRICAL

SYSTEMS. IF NOT QUALIFIED, CONTACT A QUALIFIED ELECTRICIAN.

BE CERTAIN ELECTRICAL POWER IS OFF BEFORE AND DURING INSTALLATION AND MAINTENANCE.

MAKE SURE THE SUPPLY VOLTAGE IS THE SAME AS THE

 FIXTURE'S

 RATED VOLTAGE.

TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR SHARP

OBJECTS. SUITABLE FOR DAMP LOCATIONS.

WARNING 

TO AVOID THE RISK OF FIRE, EXPLOSION OR ELECTRIC SHOCK, THIS PRODUCT SHOULD BE INSTALLED, 

INSPECTED AND MAINTAINED BY A QUALIFIED ELECTRICIAN ONLY, IN ACCORDANCE WITH ALL 

APPLICABLE ELECTRICAL CODES. 

TO AVOID ELECTRIC SHOCK: 

BE CERTAIN ELECTRICAL POWER IS OFF BEFORE AND DURING INSTALLATION AND MAINTENANCE.

PRODUCT  MUST  BE  CONNECTED TO A  WIRING  SYSTEM  WITH  AN  EQUIPMENT-GROUNDING

CONDUCTOR.  

TO AVOID EXPLOSION: 

MAKE SURE THE SUPPLY VOLTAGE IS WITHIN THE VOLTAGE RATING.

ENSURE THE MARKED T RATING IS LESS THAN THE IGNITION TEMPERATURE OF THE HAZARDOUS

ATMOSPHERE.

DO  NOT  OPERATE  IN AMBIENT  TEMPERATURES  ABOVE  THOSE  INDICATED  ON  THE PRODUCT

NAMEPLATE.

DO  NOT  OPERATE  IF THE  LENS, CORD, SEALS, HOUSING, RECEPTACLES, ETC. IS CRACKED  OR

DAMAGED. IF SO, DISCONTINUE USE AND CONTACT MANUFACTURER FOR REPLACEMENT PARTS.

ALL FASTENERS SHOULD BE PROPERLY SEATED.

WARNING: 

USER SHOULD BE TRAINED IN THE PROPER USE AND MAINTENANCE OF THIS DEVICE. WHEN EXTENSION 

CORD IS CONNECTED TO A POWER SOURCE IN HAZARDOUS AREA, PLUG AND MATCHING RECEPTACLE 

MUST BE SUITABLE FOR HAZARDOUS LOCATION INVOLVED. IMPROPER USE OF THIS DEVICE, ASSOCIATED 

PLUG, RECEPTACLE, AND CORD CAN LEAD TO SERIOUS INJURIES OR DEATH TO PERSONNEL. 

PERIODIC INSPECTION OF THE RECEPTACLE AND CORD IS NECESSARY.

 

THE CORD MUST BE ROUTINELY CHECKED FOR CUTS, BREAKS, OR ANY SEVERE ABRASIONS, AND IF ANY 

ARE FOUND, THE CORD MUST BE REPLACED BEFORE RESUMING USE OF THE UNIT.  

ELECTRICAL POWER SUPPLY MUST BE “OFF” BEFORE AND DURING INSTALLATION AND MAINTENANCE. 

INSTALLATION AND MAINTENANCE PROCEDURE MUST BE PERFORMED BY A TRAINED AND COMPETENT 

ELECTRICIAN. 

IF ANY PARTS OF THE RECEPTACLE OR PLUG APPEAR TO BE MISSING, BROKEN, OR SHOW SIGNS OR 

DAMAGE, DISCONTINUE USE IMMEDIATELY. REPLACE WITH THE PROPER REPLACEMENT PART(S) BEFORE 

CONTINUING SERVICE. 

Summary of Contents for EPLRL-50-16.4-HR-SWB

Page 1: ...D MAINTENANCE PRODUCT MUST BE CONNECTED TO A WIRING SYSTEM WITH AN EQUIPMENT GROUNDING CONDUCTOR TO AVOID EXPLOSION MAKE SURE THE SUPPLY VOLTAGE IS WITHIN THE VOLTAGE RATING ENSURE THE MARKED T RATING IS LESS THAN THE IGNITION TEMPERATURE OF THE HAZARDOUS ATMOSPHERE DO NOT OPERATE IN AMBIENT TEMPERATURES ABOVE THOSE INDICATED ON THE PRODUCT NAMEPLATE DO NOT OPERATE IF THE LENS CORD SEALS HOUSING R...

Page 2: ...herproofing all connections if installed in a location where water may come in contact with the unit Ensure the unit is properly grounded and that wiring is done according to all local and national electrical building codes INSTALLATION Stretch Applications The cable is suspended without any intermediate support Stretch reels generally require a line pull equal to two times the weight of the cable...

Page 3: ...suitable for applications requiring continuous rotation 3 A pivot base is required carousel or loop track applications 4 When a pivot base is used the reel must be mounted horizontally ceiling or floor mounted 5 The roller guide should be mounted so the cable will travel perpendicular to the axis of rotation This will guard against the cable twisting and ensure effective swivel action from the piv...

Page 4: ...process Always maintain two full cable wraps on drum at maximum cable extension size cable accordingly 1 The EXPCRL reels come with pre tension from the factory Some adjustments may be required to meet specific application requirements 2 To assure that the cable will retract properly and operate under the correct tension for intended application the reel should be tested Securely mount reel before...

Page 5: ...maximum extension to avoid excessive tension on the cable and to prevent pullout of cable from entrance watertight MAINTENANCE There are no serviceable parts inside the fixture However it is good practice to routinely clean and check the fixture for proper function Disconnect power running to the unit and be sure the fixture is cool to the touch Use a non abrasive cleaning solution to clean the fi...