background image

EPLC2-LED-150W-RT-DIMM

Larson Electronics, LLC

 

  Phone: (800) 369-6671 

 Fax: (903) 498-3364 

  www.larsonelectronics.com 

4

 of 

4

 

MAINTENANCE 

Caution: 

To avoid personal injury, disconnect power to the light and allow the unit to cool down before 

performing maintenance. 

Warning: 

No user serviceable parts inside of fixture. Risk of electric shock. Removal of the lens will void 

the warranty. 

1.

Perform visual, mechanical and electrical inspections on a regular basis. We recommend routine

checks to be made on a yearly basis. Frequency of use and environment should determine this.  It is

recommended to follow an Electrical Preventive Maintenance Program as described in NFPA 70B:

Recommended practice for Electrical Equipment.

2.

The lens should be cleaned periodically as needed to ensure continued photometric performance.

Clean the lens with a damp, non-abrasive, lint-free cloth. If not sufficient, use mild soap or a liquid

cleaner.

3.

Inspect the cooling fins on the luminaire to ensure that they are free of any obstructions or

contamination (i.e. excessive dust build-up). Clean with a non-abrasive cloth if needed.

4.

Do not operate if the lens is cracked or damaged. All fasteners should be properly seated.

USE AND CARE

Unauthorized modification may impair the function and/or safety of this device and could affect the life of the equipment. 

Always check for damaged or worn out parts before using the device. Store it in a secure place out of the reach of 

children when not in use. Inspect for good working condition prior to storage and before re-use.

 

 

REPLACEMENT PARTS

The 

EPLC2-LED-150W-RT-DIMM

 

 is designed to provide years of reliable performance. Should the need for 

replacement parts arise, please contact Larson Electronics. 

THESE INSTRUCTIONS MAY  NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS. 

SHOULD FURTHER INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL AT 

[email protected]

 OR BY PHONE AT 1-800-369-6671 FOR FURTHER ASSISTANCE. 

PLEASE VISIT LARSONELECTRONICS.COM FOR 

WARRANTY

 AND 

RETURN

 INFORMATION.

Summary of Contents for EPLC2-LED-150W-RT-DIMM

Page 1: ...THESE INSTRUCTIONS FOR FUTURE MUST BE REFERENCE THE EPLC2 LED 150W RT DIMM WIRED IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES PROPER GROUNDING IS REQUIRED FOR SAFETY WE STRONGLY ENCOURAGE ONLY A LICENSED ELECTRICIAN INSTALL OPERATE AND MAINTAIN THIS PRODUCT IF YOU ARE NOT QUALIFIED OR UNFAMILIAR WITH ANY ASPECT OF THIS INSTRUCTION SHEET CONSULT AN ELECTRICIAN THERE AR...

Page 2: ...AMEPLATE DO NOT OPERATE IF THE LENS CORD SEALS HOUSING RECEPTACLES ETC IS CRACKED OR DAMAGED IF SO DISCONTINUE USE AND CONTACT MANUFACTURER FOR REPLACEMENT PARTS ALL FASTENERS SHOULD BE PROPERLY SEATED The Larson Electronics EPLC2 LED 150W RT DIMM Explosion Proof LED Flood Light provides operators with a powerful and energy efficient alternative to traditional hazardous location luminaries Cree LE...

Page 3: ...s operators the ability to manually adjust the brightness of the LED lamp quickly and easily The 0 10V dimming allows for adjustments to fit the brightness needs of any lighting situation A 0 10V dimmable light works through the use of a DC control signal that ranges between zero and ten volts The basic idea is that at 10 volts of input the light is at its brightest level with 0 volts being the lo...

Page 4: ...aire to ensure that they are free of any obstructions or contamination i e excessive dust build up Clean with a non abrasive cloth if needed 4 Do not operate if the lens is cracked or damaged All fasteners should be properly seated USE AND CARE Unauthorized modification may impair the function and or safety of this device and could affect the life of the equipment Always check for damaged or worn ...

Reviews: