EPLC2-LED-150W-RT-DIMM

Larson Electronics, LLC

 

  Phone: (800) 369-6671 

 Fax: (903) 498-3364 

  www.larsonelectronics.com 

3

 of 

4

 

Use only 0-10V Dimmer appropriate for the location installed. 
WARNING:

 

Mis-wiring Low Voltage Dimming Control could cause permanent damage to light.

DO NOT

 connect dimming control to line voltage. 

DO NOT

 connect dimmer with power applied. 

WIRE(AC) 

WIRE(DC) 

COLORED CABLE 

AC LIVE 

DC LIVE 

BLACK 

AC NEUTRAL  DC NEUTRAL 

WHITE 

GROUND 

GROUND 

GREEN 

D  D 

RED 

DIMMING - 

DIMMING - 

ORANGE 

WARNING:

 CHECK NAMEPLATE FOR PROPER VOLTAGE. 

DAMAGE FROM IMPROPER VOLTAGE WILL VOID WARRANTY. 

DIMMING

 

This LED light fixture features 0-10V dimming capabilities. This gives operators the ability to manually adjust 

the brightness of the LED lamp quickly and easily. The 0-10V dimming allows for adjustments to fit the 

brightness needs of any lighting situation. A 0-10V dimmable light works through the use of a DC control signal 

that ranges between zero and ten volts. The basic idea is that at 10 volts of input the light is at its brightest 

level with 0 volts being the lowest possible dimness setting. The smooth, continuous and flicker-free dimming 

of a 0-10V dimmable LED light is ideal for a wide range of different lighting applications.

Voltage:

 

Check product label for correct voltage. 

WIRING 

(see attached wiring diagram)

 

This unit comes preconfigured in selected voltage and beam configuration. Wire light to the correct 
voltage. Follow all applicable local, state, and National Electrical Code for the hazardous area.

 

Wire size is 18/5.

 

  

Summary of Contents for EPLC2-LED-150W-RT-DIMM

Page 1: ...THESE INSTRUCTIONS FOR FUTURE MUST BE REFERENCE THE EPLC2 LED 150W RT DIMM WIRED IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES PROPER GROUNDING IS REQUIRED FOR SAFETY WE STRONGLY ENCOURAGE ONLY A LICENSED ELECTRICIAN INSTALL OPERATE AND MAINTAIN THIS PRODUCT IF YOU ARE NOT QUALIFIED OR UNFAMILIAR WITH ANY ASPECT OF THIS INSTRUCTION SHEET CONSULT AN ELECTRICIAN THERE AR...

Page 2: ...AMEPLATE DO NOT OPERATE IF THE LENS CORD SEALS HOUSING RECEPTACLES ETC IS CRACKED OR DAMAGED IF SO DISCONTINUE USE AND CONTACT MANUFACTURER FOR REPLACEMENT PARTS ALL FASTENERS SHOULD BE PROPERLY SEATED The Larson Electronics EPLC2 LED 150W RT DIMM Explosion Proof LED Flood Light provides operators with a powerful and energy efficient alternative to traditional hazardous location luminaries Cree LE...

Page 3: ...s operators the ability to manually adjust the brightness of the LED lamp quickly and easily The 0 10V dimming allows for adjustments to fit the brightness needs of any lighting situation A 0 10V dimmable light works through the use of a DC control signal that ranges between zero and ten volts The basic idea is that at 10 volts of input the light is at its brightest level with 0 volts being the lo...

Page 4: ...aire to ensure that they are free of any obstructions or contamination i e excessive dust build up Clean with a non abrasive cloth if needed 4 Do not operate if the lens is cracked or damaged All fasteners should be properly seated USE AND CARE Unauthorized modification may impair the function and or safety of this device and could affect the life of the equipment Always check for damaged or worn ...

Reviews: