WIRE DIAGRAM 

ALL ELECTRICAL WORK SHOULD BE PERFORMED BY A QUALIFIED ELECTRICIAN. 

Be sure the voltage and cycles shown on the motor nameplate correspond to the power supply. Check product 
nameplate for Ratings and Approvals. This fan is rated for single phase 115V or 230V AC 60Hz operation.

 

Refer to the diagram below, also located inside the terminal box cover or on the nameplate. BE SURE TO 
CONNECT FOR THE VOLTAGE, FREQUENCY AND PHASE TO BE USED. 

Before activating fan, inspect to be sure 
that there are no obstructions or debris 
that would interfere with the propeller. 
Check all fasteners for tightness. 

Exp Cord Cap 

Position  device  near  work  area  for  operation.  Run  cable  to  nearby  power 

source. Insert and twist-lock explosion-proof plug into a compatible receptacle within 

the hazardous environment. See 

plug operation

 below. 

PLUG OPERATION 

Electrical connection between plug and compatible receptacle is accomplished 

after plug fully inserts into receptacle and rotated clockwise. 

1.

Lift receptacle door and locate polarization on mating plug pin and

 

receptacle face. Insert plug straight 

all the way into receptacle until it

 

cannot go further.

2.

Rotate plug clockwise limit (37º), this closes internal contacts and

 

completes circuit. This also 

mechanically locks plug into receptacle so it

 

cannot be pulled out.

3.

To remove plug, push plug inward and turn to counterclockwise, pull plug

 

straight out.