background image

EPF-30-PM-EYM-25-EPP

Larson Electronics, LLC

 

  Phone: (800) 369-6671 

 Fax: (903) 498-3364 

  www.larsonelectronics.com 

1

 of 

2

 

WARNING 

TO AVOID THE RISK OF FIRE, EXPLOSION OR ELECTRIC SHOCK, THIS PRODUCT SHOULD BE INSTALLED, 

INSPECTED AND MAINTAINED BY A QUALIFIED ELECTRICIAN ONLY, IN ACCORDANCE WITH ALL 

APPLICABLE ELECTRICAL CODES. 

TO AVOID ELECTRIC SHOCK: 

BE CERTAIN ELECTRICAL POWER IS OFF BEFORE AND DURING INSTALLATION AND MAINTENANCE.

PRODUCT  MUST  BE  CONNECTED TO A  WIRING  SYSTEM  WITH  AN  EQUIPMENT-GROUNDING

CONDUCTOR.  

TO AVOID EXPLOSION: 

MAKE SURE THE SUPPLY VOLTAGE IS WITHIN THE VOLTAGE RATING.

ENSURE THE MARKED T RATING IS LESS THAN THE IGNITION TEMPERATURE OF THE HAZARDOUS

ATMOSPHERE.

DO  NOT  OPERATE  IN AMBIENT  TEMPERATURES  ABOVE  THOSE  INDICATED  ON  THE PRODUCT

NAMEPLATE.

DO  NOT  OPERATE  IF THE  LENS, CORD, SEALS, HOUSING, RECEPTACLES, ETC. IS CRACKED  OR

DAMAGED. IF SO, DISCONTINUE USE AND CONTACT MANUFACTURER FOR REPLACEMENT PARTS.

ALL FASTENERS SHOULD BE PROPERLY SEATED.

WARNING: 

USER SHOULD BE TRAINED IN THE PROPER USE AND MAINTENANCE OF THIS DEVICE. IF WIRING OR LAMP REPLACEMENT 

INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, THE HANDLAMP MAY NOT BE SUITABLE FOR THE HAZARDOUS LOCATION INVOLVED. 

WHEN HANDLAMP IS CONNECTED TO A POWER SOURCE IN HAZARDOUS AREA, PLUG AND MATCHING RECEPTACLE MUST BE SUITABLE 

FOR HAZARDOUS LOCATION INVOLVED. WHEN HANDLAMP IS CONNECTED TO POWER SOURCES OUTSIDE OF HAZARDOUS AREA, 

STANDARD DUTY PLUGS AND RECEPTACLES MAY BE USED.  

STANDARD PLUG AND TRANSFORMER MUST ONLY BE CONNECTED TO A RECEPTACLE LOCATED OUTSIDE THE 

HAZARDOUS AREA! 

IMPROPER USE OF THIS HANDLAMP, ASSOCIATED PLUG, RECEPTACLE, AND CORD CAN LEAD TO SERIOUS INJURIES OR DEATH TO 

PERSONNEL. 

PERIODIC INSPECTION OF THE HANDLAMP AND CORD IS NECESSARY.

 

THE CORD MUST BE ROUTINELY CHECKED FOR CUTS, BREAKS, OR ANY SEVERE ABRASIONS, AND IF ANY ARE FOUND, THE CORD MUST 

BE REPLACED BEFORE RESUMING USE OF THE HANDLAMP.  

THE GLOBE IS MADE OF TEMPERED GLASS. IF THIS GLASS BECOMES SCRATCHED OR CHIPPED IT SHOULD BE REPLACED IMMEDIATELY. 

The Larson Electronics EPF-30-PM-EYM-25-EPP Explosion Proof Circular Fan redirects and circulates air within 

hazardous locations. This explosion proof fan meets UL standards for hazardous areas and provides a high 8,723 CFM 

output for effective airflow in larger spaces.

WIRING 

This explosion proof fan is equipped with 25 foot of 16/3 chemical and abrasion resistant SOOW cord that is fitted with an 

explosion proof cord cap for easy connection to explosion proof outlets. Plug options include a 5-15 15 amp straight blade 

plug for use with 120V explosion proof outlets, a 5-20 20 amp straight blade plug for use with 120V explosion proof outlets, 

or a 6-20 20 amp straight blade plug for use with 220-240V explosion proof outlets.

We strongly encourage a licensed electrician install this product

, in all locations especially in outdoor areas 

where weatherproofing may be required. Universal voltage driver permits operation at 

115V or 230V AC.

Warning: 

Check product label for correct input voltage!

 

Attach supply line wires to the appropriate light fixture wires as shown in the

 wiring

 diagram

.

Secure  each  pair  of  wires  according  to  the  diagram.  Utilize  a  junction  box  or  similar  device  and  take 

precautionary steps for weatherproofing all connections if installed in a location where water may come in contact 

with the unit. Ensure the unit is properly grounded and that wiring is done according to all local and national electrical/

building codes. 