Warning!
For ATEX / IECEx GROUP II applications, ONLY Duracell Plus MN1500,
Duracell ID1500, Energizer E91 or Panasonic LR6XWA cells may be used
with the
camera
(see Table 1).
Warning!
For MET applications, ONLY Duracell Plus MN1500, Duracell ID1500
or Energizer E91 cells may be used with the
camera
(see Table 1).
Warning!
For ATEX / IECEx GROUP I applications, ONLY Duracell Plus MN1500
and Duracell ID 1500 cells may be used with the
camera
(see Table 1).
Warning!
For ATEX / IECEx GROUP II and MET applications ONLY, the user shall
not carry more than a maximum of 2 spares of the approved cells listed
above into the hazardous area. Precautions shall be taken to prevent
short circuiting of un-protected cell terminals. Discharged cells shall be
removed from the hazardous area.
Warning!
For ATEX / IECEx GROUP I applications, the changing of cells in the
hazardous area or the transportation of spare cells into the hazardous
area is NOT PERMITTED.
Warning!
NOTE THE DIFFERENT TEMPERATURE CLASSSIFICATION of T3
/
T3C
when Energizer E91 or Panasonic LR6XWA cells are used (see Table 1).
Warning!
The user shall NOT mix different cells in ANY application
Warning!
For ATEX / IECEx GROUP II applications, note that the rated ambient
temperature range of the equipment is from -20
o
C to 60
o
C.
Warning!
For ATEX / IECEx GROUP I applications, note that the rated ambient
temperature range of the equipment is from 0
o
C to 60
o
C.
Warning!
For MET applications, note that the rated ambient temperature range of
the equipment is from -20
o
C to 55
o
C.
Warning!
Any connection to the
camera
USB port must NOT be made in a
hazardous area.
Warning!
If any damage to the
camera
is found which may invalidate the required
safety minimum IP rating (IP54 for group I applications), (IP20 for
group II), the
camera
shall be removed from the hazardous area.
Important
Any repairs or replacement of parts MUST be performed by the
manufacturer or its nominated sub-contractor or agent.
Important
The
camera
contains no user serviceable parts. The main part of the
enclosure must not be opened under any circumstances.
ATX-EXPCMR-BP-HH-QXGA
Larson Electronics, LLC
Phone: (877) 348-9680
Fax: (903) 498-3364
www.larsonelectronics.com
4
of
10