9/29/09
C -11
.
RMS Measurement Range (LOG and ISM modes only)
Electrical
Noise Floor
Low
Limit
High
Limit
Range
Pulse
Range
A-WT (high)
< 22
< 43
151
> 108
> 108
A-WT (normal)
< 12
< 23
131
> 108
> 108
A-WT (low)
< 10
< 20
111
> 91
> 91
C-WT (high)
< 38
< 48
151
> 103
> 103
C-WT (normal)
< 18
< 28
131
> 103
> 103
C-WT (low)
< 14
< 25
111
> 86
> 86
FLAT (high)
< 40
< 50
151
> 101
> 101
FLAT (normal)
< 20
< 30
131
> 101
> 101
FLAT (low)
< 15
< 25
111
> 86
> 86
Summary of Contents for System 824
Page 1: ...Model 824 Precision Sound Level Meter Real Time Analyzer Reference Manual...
Page 2: ......
Page 3: ...I824 01 Rev P Technical Reference Manual Larson Davis Model 824...
Page 58: ...2 18 824 Reference Manual 9 29 09...
Page 120: ...4 24 824 Reference Manual 9 29 09...
Page 194: ...5 74 824 Reference Manual 9 29 09...
Page 284: ...7 80 824 Reference Manual 9 29 09...
Page 312: ...8 28 824 Reference Manual 9 29 09...
Page 330: ...9 18 824 Reference Manual 9 29 09...
Page 366: ...10 36 824 Reference Manual 9 29 09...
Page 460: ...A 4 824 Reference Manual 9 29 09 shown below Both versions work properly with the Model 824...
Page 538: ...A 82 824 Reference Manual 9 29 09...
Page 546: ...B 8 824 Reference Manual 9 29 09...
Page 569: ...9 29 09 C 23 Windscreen Response with Respect to No Windscreen...
Page 596: ...C 50 824 Reference Manual 9 29 09...
Page 630: ...E 10 824 Reference Manual 9 29 09...
Page 638: ...F 8 824 Reference Manual 9 29 09...
Page 648: ...G 10 824 Reference Manual 9 29 09...
Page 672: ...iv xxiv Index Model 831 Technical Reference Manual...