6
TORNADO 2
English
OFF (0)
OFF (0)
ON (I)
Should anyone use an extension cable between
the tooling and the socket, it must have the same
characteristics as the cable supplied (
minimum
diameter of the wire 2.5 mm
2
) with a maximum
length of 50 mt. Higher lengths and lower diameters can
provoke excessive voltage falls and also an anomalous
working of the equipment.
CONNECTION OF THE TOOLING TO THE POWER SUPPLY
• Check
the
switch
(
F3
) is on the "
OFF"
(0)
position before
connecting the cable to the mains.
•
Place the pressure control knob (
F4
) on the “
MIN
” position
(
turn counterclockwise
).
It is
ADVISED
to mount a high pressure manometer at the
pump outlet (
see on page “Accessories”
) to read the product
pressure.
•
It is recommended to use the hose provided with the standard
kit (
ref.18036
).
NEVER
use a damaged or a repaired fl exible hose.
CHECK ON POWER SUPPLY
•
Check the plant is earthed.
•
Check the mains voltage corresponds to the equipment’s
rating.
•
The supply cable is provided without plug.
Use a plug which guarantees the plant earthing.
Only a technician or a skilled person should perform the
connection of the plug to the electric cable.
F4
F3
Voltaggio
Voltaggio