11
TORNADO 2
English
OFF (0)
OFF (0)
ON (I)
M
CORRECT PROCEDURE OF DECOMPRESSION
•
Insert the gun clamp (
M1
).
•
Move the switch (
M2
) to the
OFF
(0)
position to stop the
equipment.
WARNING
:
If the equipment is still under pressure after performing the operations above described
because of the nozzle or the flexible hose clogged, proceed as follows:
•
Loosen very slowly the gun nozzle.
•
Release the clamp.
• Point the gun at the container of the product and press the trigger to release
pressure.
•
Loosen very slowly the fi tting of connection from the fl exible hose to the gun.
•
Clean or replace the fl exible hose and the nozzle.
•
Disconnect the power supply cable (
M3
).
•
Release the gun clamp (
M4
), point the gun at the tank of the
product and press the trigger to release pressure. At the end
of the operation, insert the gun clamp.
•
Open the drain valve (
M5
) to release the residual pressure
always clockwise.
M2
M4
M5
M3
M1