![Larius New Excalibur Operating And Maintenance Instruction Manual Download Page 18](http://html1.mh-extra.com/html/larius/new-excalibur/new-excalibur_operating-and-maintenance-instruction-manual_676418018.webp)
F7
F5
F6
Ed. 015 - 02/2019
www.larius.eu
NEW EXCALIBUR
14
Circulation and
washing
•
Visually check that the wash fluid starts to re-circulate
within the tank (
F7
).
•
Turn the pressure adjustment handle (
F5
) clockwise to
stop the pump.
•
Closed the recirculating-safety valve (
F6
).
•
Turn pressure regulating knob (
F5
) clockwise a little so
that the machine idles.
•
Open the recirculating-safety valve (
F6
).
•
Turn the pressure setting knob (
F5
) clockwise to the “CIR-
CULATION & WASHING” position
(drop symbol)
.
OpeN
It re-circulates back into
the tank without spraying
CLOseD
It sprays out of the spray
gun
Circulation
and washing
F6
F6
F5
F5
F5