![Larius MIRO Series Operating And Maintenance Instruction Manual Download Page 17](http://html1.mh-extra.com/html/larius/miro-series/miro-series_operating-and-maintenance-instruction-manual_676417017.webp)
English
15
OIL
I
ROUTINE MAINTENANCE
TOP UP HYDRAULIC OIL
With each start up, check the hydraulic oil level by looking through
the gauge (
I1
) on the side of the hydraulic body. If necessary, use
“
AGIP OSO 46 type hydraulic oil
”
to top up the level.
RELEASE THE SUCTION VALVE
If the pump malfunctions, release the suction valve fitted on the
head of the pump in the following way:
•
Remove the suction hose fitting (
Mirò horizontal version
) or
the suction tank (
Mirò vertical version
) and release the valve
by inserting a rigid rod (
I2
) with a diameter of no more than
15 mm.
To facilitate this operation add a few drops of oil.
CLEANING THE COMPRESSION VALVE
If the machine has problems with sucking up the liquid, disassemble
the compression valve (
I3
), and clean it with solvents that are
specifically for the type of paint being used.
Once it has been cleaned, shake the valve (
I3
) by hand to check
that the ball inside moves freely in its seating. If necessary,
clean again.
I1
I2
I3
I3
I3