Read the indications provided in the user and
maintenance manual carefully prior to installation.
All of the maintenance operations must be
performed according to the indications provided
in the manual.
GHIBLI series pneumatic piston transfer pump
cannot work without material.
All of the installation and maintenance operations
must be performed by qualified personnel.
www.larius.com
25
GHIBLI 10:1 PNEUMATIC WASHING PUMP
REV.
02 - 06/2021 - Cod. 150186
NOTE
* Fluid temperature
can be 90° maximum
only with water or
water based
products
MARKINGS
3
X
II 2 G c IIB T6 T
amb
: -20°C ÷ + 60°C T
max.
fluid: 90°C Tech. File: GHIBLI/ATX/08
II =
Group II (surfaces)
2 =
Category 2 (zone 1)
G =
Explosive atmosphere containing gasses, vapours or
mists
c =
Design safety “c”
T6 =
Temperature class T6
- 20°C ÷ + 60°C
Room temperature
90°C
Maximum process fluid temperature
xxxx/AA
Serial number or lot number (xxxxx = PROGRESSIVE /
year = AA)
HAZARDOUS AREAS
CATEGORIES ACCORDING TO THE 94/9/CE DIRECTIVE
Gasses, vapours or mists
Zone 0
1G
Gasses, vapours or mists
Zone 1
2G or 1G
Gasses, vapours or mists
Zone 2
3G, 2G or 1G
Correspondence between hazardous areas, substances and categories
• The grounding wire for the pumps indicated above must be
grounded using an appropriate anti-loosening connection.
• The tubes used to connect the delivery and suction lines
must be either metallic, plastic with metallic braid, or plastic
with fabric braid and a suitable grounding conductor.
• The pumps must be installed on properly grounded
metallic or antistatic drums.
• The gases or vapours of any flammable liquids present
must belong to group IIB.
• Based on the type of use and the substances employed,
the user must periodically check for any encrustations
and must verify the cleanliness, the wear status and the
correct functionality of the pump on a regular basis.
• The user must periodically clean the suction filter in order
to prevent any solid materials from entering the pump.
The air used to power the pump must be filtered and
must come from a SAFE AREA.
SAFETY INSTRUCTIONS FOR INSTALLATION IN HAZARDOUS AREAS
We Larius S.r.l.
Via Stoppani, 21
23801 Calolziocorte (LC)
declare under our sole responsability that the product:
GHIBLI series pneumatic piston transfer pump.
to which this declaration relates complies with the following
directives:
- Directive 94/9/EC (ATEX)
The conformity are under observance of the following standards
or standards documents:
- EN 1127-1 - EN 13463-5
- EN 13463-1
Markings
II 2 G c IIB T6 Tamb.: - 20°C ÷ 60°C Tmax. fluido (acqua): 90°C*
Tech. File::
GHIBLI/ATX/08
Technical dossier kept on file c/o:
INERIS (0080)
Calolziocorte- LC, 15/12/2008
Signature (LARIUS)
* water or water based product
3
X
DECLARATION OF CONFORMITY