background image

www.larius.com

12

PREHETAER

REV. 01 - 12/2021 - Cod. 150196

ATEX CERTIFICATE

MARKINGS

• 

Temperatura amb.:

 ÷ +90°C       

3

X

             

II    3 G  nC   IIB   T3 Gc    Tech file: PREHEATER/ATX/12    

Correspondence between dangerous areas, substances and grade

Before installation, carefully read the information in 
the use and maintenance manual. All maintenance 
operations must be carried out according to the 
instructions in the manual.

Do not open the preheater when powered. To 
open the lid, disconnect the power and wait at 
least 30 minutes.

•  The preheater must be installed and maintained in accordance 

with  the  installation  and  maintenance  standards  for 
environments classified against the risk of explosion due to 
the presence of gases and vapors (example: EN60079-14, 
EN 60079-17 or other national regulations/standards).

SAFETY INSTRUCTIONS FOR THE INSTALLATION IN DANGEROUS AREAS

II =     

Group II ( surface)

3 =

Grade 3 (zone 2)

G =

Explosive environment with gas, vapour or mist

Ex nC =

Mode of protection (sparkling protect nC)

IIB

Gas group (IIB)

T3

Class of temperature (T4)

Gc

EPL (gas)

Tech file

Techical file

DANGEROUS AREA 

GRADE ACCORDING TO

DIRECTIVE 94/9/CE

EPL

Gas, vapour or mist

Zone 0

1G

Ga

Gas, vapour or mist

Zone 1

2G or 1G

Gb or Ga

Gas, vapour or mist

Zone 2

3G, 2G or 1G

Gc, Gb or Ga

J

Check that the polyurethane foam inserted in the 
lid is not damaged.

The preheater must be properly earthed by means 
of the anti-loosening and anti-rotating device.
Make sure that the earthing of the preheater is 
always guaranteed and ensured.

The user must periodically check, depending on the type of use and the substances used:

•   the state of wear and correct operation of the preheater;
•   the presence of abnormal vibrations and/or noises. In this case, stop the preheater, identify the causes and contact the manufacturer.

Nonetheless, residual risks may be present during normal preheater operation if:
•  is not subject to the normal maintenance plans provided for in the use and maintenance manual;
•  is not used as required by the project specifications.

Summary of Contents for 6099

Page 1: ...w w w l a r i u s c o m REV 01 12 2021 Manuale Cod 150197 OPERATING AND MAINTENANCE MANUAL EN PREHEATER Cod 6099 Version 220 V Cod 6990 Version 400 V ...

Page 2: ...manual without prior notice This manual is to be considered as an English language translation of the original manual in Italian The manufacturer shall bear no responsibility for any damages or inconveniences that may arise due to the incorrect translation of the instructions contained within the original manual in Italian ...

Page 3: ...r choosing a LARIUS S R L product As well as the product purchased you will receive a range of support services enabling you to achieve the results desired quickly and professionally INDEX WARNINGS 4 TRANSPORT AND UNPACKING 5 CONDITIONS OF GUARANTEE 5 SAFETY RULES 5 TECHNICAL DATA 6 WORKING PRINCIPLE 7 ROUTINE MAINTENAINCE 8 ELECTRICAL CONNECTIONS 8 EXPLODED VIEW OF THE PREHEATER 10 ATEX CERTIFICA...

Page 4: ...ry out the decompression procedure explained in this manual and prevent any risk of the equipment starting unexpectedly Report any risk of chemical reaction or explosion if this warning has not been given IF PROVIDED There is a risk of injury or serious lesion related to contact with the jet from the spray gun If this should occur IMME DIATELY contact a doctor indicating the type of product inject...

Page 5: ... ABOUT THE USE OF SAFETY DEVICES FOR THEIR OWN SAFETY AND ABOUTTHEGENERALRULESFORACCIDENTPREVENTION INCOMPLIANCEWITHINTERNATIONALREGULATIONSAND WITH THE LAWS OF THE COUNTRY WHERE THE PLANT IS USED THE BEHAVIOUR OF THE EMPLOYEES SHALL STRICTLY COMPLY WITH THE ACCIDENT PREVENTION AND ALSO ENVIRONMENTALREGULATIONSINFORCEINTHECOUNTRY WHERE THE PLANT IS INSTALLED AND USED KEEP YOUR WORK PLACE CLEAN AND...

Page 6: ...kingorunderpressure A sudden movement of the piston rod can cause wounds or finger squashing Neversprayoverflammableproductsorsolvents in closed places Never use the tooling in presence of potentially explosive gas Always check that the product is compatible with the materials composing the equipment pump spray gun flexible hose and accessories with which it can come into contact Never use paints ...

Page 7: ...to the power line has been made The fluid is heated through an electrical resistor that sends the heat generated to the spiral stainless steel tube that flows inside the preheater body The temperature of the fluid detected by the thermometer 2 can be adjusted by acting on the appropriate adjustment knob 3 The switching on of the red temperature indicator light 4 indicates that the chosen temperatu...

Page 8: ...disconnect the power supply before carrying out any type of check or replacement of the electrical components of the preheater ELECTRICAL CONNECTIONS To access the inside of the preheater remove the front cover H1 First of all check the continuity of the electric cables and the fuses To replace the indicator light bulb if necessary do not try to remove the front ring nut H2 but unscrew the glass l...

Page 9: ...ETAER REV 01 12 2021 Cod 150196 NOTE After replacing each electrical component check the correct connection of the cables Fig 5H Fig 4H Red light Green light 2 1 P1 To replace the heating element H6 remove the case H7 H7 H6 ...

Page 10: ... REV 01 12 2021 Cod 150196 I 1 2 3 4 3 5 12 11 13 7 8 9 10 14 15 16 18 19 20 21 22 23 24 25 22 26 27 22 28 24 29 31 32 33 22 22 26 34 27 35 28 36 37 39 40 41 42 38 43 48 44 33 32 46 47 45 6 17 30 49 EXPLODED VIEW OF THE PREHEATER ...

Page 11: ... 6123 Thermostat plate 1 20 6122 Thermostat 1 21 5339 Screw 2 22 5737 Washer 6 23 6108 Fuse holder vers 220V 2 6108 1 Fuse holder vers 400V 2 24 9308 Screw 4 Pos Code Description Q ty 25 6109 Fuse vers 220V 2 6109 1 Fuse vers 400V 2 26 6112 Grounding 2 27 6113 Grounding plate 2 28 6111 Screw 2 29 6138 Safety thermostat only vers 220V 1 30 32024 Washer 4 31 6151 Screw 4 32 107 Plastic plug 2 33 813...

Page 12: ...environment with gas vapour or mist Ex nC Mode of protection sparkling protect nC IIB Gas group IIB T3 Class of temperature T4 Gc EPL gas Tech file Techical file DANGEROUS AREA GRADE ACCORDING TO DIRECTIVE 94 9 CE EPL Gas vapour or mist Zone 0 1G Ga Gas vapour or mist Zone 1 2G or 1G Gb or Ga Gas vapour or mist Zone 2 3G 2G or 1G Gc Gb or Ga J Check that the polyurethane foam inserted in the lid i...

Page 13: ...www larius com 13 PREHETAER REV 01 12 2021 Cod 150196 ...

Page 14: ...LARIUS srl Via Antonio Stoppani 21 23801 Calolziocorte LC ITALY TEL 39 0341 621152 Fax 39 0341 621243 larius larius com www larius com ...