www.larius.com
12
PREHETAER
REV. 01 - 12/2021 - Cod. 150196
ATEX CERTIFICATE
MARKINGS
•
Temperatura amb.:
÷ +90°C
3
X
II 3 G nC IIB T3 Gc Tech file: PREHEATER/ATX/12
Correspondence between dangerous areas, substances and grade
Before installation, carefully read the information in
the use and maintenance manual. All maintenance
operations must be carried out according to the
instructions in the manual.
Do not open the preheater when powered. To
open the lid, disconnect the power and wait at
least 30 minutes.
• The preheater must be installed and maintained in accordance
with the installation and maintenance standards for
environments classified against the risk of explosion due to
the presence of gases and vapors (example: EN60079-14,
EN 60079-17 or other national regulations/standards).
SAFETY INSTRUCTIONS FOR THE INSTALLATION IN DANGEROUS AREAS
II =
Group II ( surface)
3 =
Grade 3 (zone 2)
G =
Explosive environment with gas, vapour or mist
Ex nC =
Mode of protection (sparkling protect nC)
IIB
Gas group (IIB)
T3
Class of temperature (T4)
Gc
EPL (gas)
Tech file
Techical file
DANGEROUS AREA
GRADE ACCORDING TO
DIRECTIVE 94/9/CE
EPL
Gas, vapour or mist
Zone 0
1G
Ga
Gas, vapour or mist
Zone 1
2G or 1G
Gb or Ga
Gas, vapour or mist
Zone 2
3G, 2G or 1G
Gc, Gb or Ga
J
Check that the polyurethane foam inserted in the
lid is not damaged.
The preheater must be properly earthed by means
of the anti-loosening and anti-rotating device.
Make sure that the earthing of the preheater is
always guaranteed and ensured.
The user must periodically check, depending on the type of use and the substances used:
• the state of wear and correct operation of the preheater;
• the presence of abnormal vibrations and/or noises. In this case, stop the preheater, identify the causes and contact the manufacturer.
Nonetheless, residual risks may be present during normal preheater operation if:
• is not subject to the normal maintenance plans provided for in the use and maintenance manual;
• is not used as required by the project specifications.