4. Important Safety Warning (SAVE THESE INSTRUCTIONS) 

CAUTION! 

To prevent the risk of fire or electric shock, install the UPS in a temperature and 

humidity  controlled  indoor  area,  free  of  conductive  contaminants.  (See  specifications  for 
acceptable temperature and humidity ranges.) 

CAUTION! 

To  reduce  the  risk  of  overheating  the  UPS,  do  not  cover  the  UPS'  cooling  vents 

and avoid exposing it to direct sunlight or installing it near heat emitting appliances, such as 
space heaters or furnaces. 

CAUTION! 

Do  not  attach  to  UPS  non-computer-related  items,  such  as  medical  equipment, 

life-support equipment, microwave ovens, or vacuum cleaners. 

CAUTION! 

Do not plug the UPS input into its own output. 

CAUTION!

  Do  not  allow  liquids  or  any  foreign  object  to  enter  the  UPS.  Do  not  place 

beverages or any other liquid-containing vessels on or near the unit.  

CAUTION!

  In  case  of  an  emergency,  press  the  OFF  button  and  disconnect  the  power  cord 

from the AC power supply to properly disable the UPS. 

CAUTION! 

Do not attach a power strip or surge suppressor to the UPS. 

CAUTION! 

With  the  installation  of  this  equipment,  it  should  be  prevented  that  the  sum  of 

the leakage current of the UPS to the connected consumer exceeds 3.5mA. 

Attention

  hazardous  through  electric  shock.  Even  disconnecting  this  unit  from  the  mains, 

hazardous  voltage  still  may  be  accessible  through  supply  from  battery.  The  battery  supply 
should be  therefore disconnected in the  plus  and minus  pole at the  quick connectors of the 
battery when maintenance or service work inside the UPS is necessary. 

CAUTION! 

Servicing  of  batteries  should  be  performed  or  supervised  by  people 

knowledgeable of batteries and the required precautions. Keep unauthorized personnel away 
from batteries.  

CAUTION! 

When replacing the batteries, use the same number and type of batteries. 

CAUTION! 

Internal battery voltage is 12VDC. Sealed, lead-acid, 6-cell battery. 

CAUTION! 

Do  not  dispose  of  batteries  in  a  fire.  The  battery  may  explode.  Do  not  open  or 

mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes. 

CAUTION!

 Unplug the UPS prior to cleaning and do not use liquid or spray detergent. 

CAUTION! 

A battery can present a risk of electric shock and high short circuit current. The 

following precaution should be observed before replacing batteries: 

1)  Remove watches, rings, or other metal objects. 
2)  Use tools with insulated handles. 
3)  Wear rubber gloves and boots. 
4)  Do not lay tools or metal parts on top of batteries. 
5)  Disconnect charging source prior to connecting or disconnecting batteries terminal. 

 

 
 
 
 
 
 
 
 

5. Software Download & Installation (Only for the model with 
communication port) 

Please follow steps below to download and install monitoring software: 

1. Insert supplied CD or go to the website 

http://www.power-software-download.com

 

2.  Click  ViewPower  software  icon  and  then  choose  your  required  OS  to  download  the 
software.  
3. Follow the on-screen instructions to install the software. 
4. When your computer restarts, the monitoring software will appear as an orange plug icon 

located in the system tray, near the clock. 

 
6. Trouble Shooting 

Use the table below to solve minor problems. 

Problem 

Possible Cause 

Solutions 

No words display on 
the front panel. 

Low battery. 

Charge the UPS at least 6 hours. 

Battery fault. 

Replace the battery with the same 
type of battery. 

The UPS is not turned on. 

Press the power switch again to turn 
on the UPS. 

Alarm sounds 
continuously when 
the  
mains is normal. 

The UPS is overload. 

Remove some loads first. Before 
reconnecting them, please verify that 
the load matches the UPS capability. 

When power fails, 
back-up time is too 
short 

The UPS is overload. 

Remove some critical load. 

Battery voltage is too low. 

Charge the UPS at least 6 hours. 

Battery defect. It might be 
due to high temperature 
operation environment, or 
improper operation to 
battery. 

Replace  the  battery  with  the  same 
type of battery. 

The mains is normal  
But the unit is on 
battery mode. 

Power cord is loose. 

Reconnect the power cord properly. 

 
 
 
 
 
 
 
 
 
 
 
 
 