5.7.

 

FFC(Flat-Field Correction) 

Figure 17 represents the difference between the image applied Flat-Field correction and 
the image not applied Flat-Field correction. 
 

               

 

Figure 17. LPMVC-CL025M Flat-Field correction On/Off compared image 

 

If  Flat-Field  correction  isn’t  executed,  the  non-uniformed  pixels  will  appear  due  to  the 
difference of the illuminance in the sensor manufacturing process. 

5.8.

 

Black Level Compensation 

If  the  temperature  of  the  sensor  rises,  the  sharpness  of  the  image  quality  will  fall 
because of “the Blurred Image Phenomenon”

.

 

User  can  correct  “the  Blurred  Image  Phenomenon”  by  using  the  function  of  the  Black 
Level  Compensation.  User  can  adjust  the  value  of  the  Black  Level  Compensation 
according to the degree of “the Blurred Image Phenomenon”. 
The  sensor  of  LPMVC-CL025M  provides  the  function  of  the  auto  calibration,  and  the 

range of the Black Level Compensation value is 

0 ~ 255

』.

 

 

 

 

92

 

107

 

76

 

107

 

95

 

125

 

125

 

126

 

126

 

Summary of Contents for LPMVC-CL025M

Page 1: ...2016 03 04 LPMVC CL025M User Manual Version 1 0...

Page 2: ...n 11 3 Camera Specification 12 3 1 Overview 12 3 2 Key Features 13 3 3 Technical Specifications 14 3 4 Sensor Information 15 3 4 1 Sensor Optical Chart 15 3 5 Mechanical Specifications 15 3 5 1 Outlin...

Page 3: ...C Flat Field Correction 31 5 8 Black Level Compensation 31 5 9 Camera Output Timing Chart 32 5 9 1 Horizontal Timing Chart 32 5 9 2 Vertical Timing Chart 35 5 10 Trigger Mode 37 5 10 1 Free Run Mode 3...

Page 4: ...ime 52 6 4 4 Frame Rate 52 6 4 5 PRNU 52 6 4 6 FFC 52 6 4 7 Black Level 53 6 4 8 FILTER 53 6 5 Trigger Strobe Tab 54 6 5 1 Trigger 54 6 5 2 Trigger Polarity 54 6 5 3 Sensor Exposure Time 55 6 5 4 Trig...

Page 5: ...C CL025M Test Patterns 29 Figure 16 LPMVC CL025M PRNU correction On Off compared image 30 Figure 17 LPMVC CL025M Flat Field correction On Off compared image 31 Figure 18 Horizontal Timing Chart of 2Ta...

Page 6: ...ULaTor StartUp Success Message 47 Figure 39 CULaTor About Menu 48 Figure 40 CULaTor About Dialog 48 Figure 41 CULaTor Main Tab 49 Figure 42 CULaTor Control Tab 51 Figure 43 CULaTor Trigger Strobe Tab...

Page 7: ...VC CL025M Camera Link Connector 2 19 Table 4 Description of each Data bits for 8Tap 8bit 20 Table 5 Description of each Data bits for 10Tap 8bit 21 Table 6 Camera Link TAP Port Assignments 23 Table 7...

Page 8: ...More than Imaging Laon People 8 2016 03 04 Revision History Revision Date Comments 1 0 2016 02 22 Initial release...

Page 9: ...e occurred in the following reasons users must pay for the repairs In case of a fault due to the carelessness of the customer In case of a fault due to a natural disaster fire earthquake flood lightni...

Page 10: ...serial number label Do not damage disassemble repair or alter the device Do not place the device next to heating equipment Do not use the device for any other purpose then specified Do not install the...

Page 11: ...the camera in a place subject to unstable lighting condition strong vibration Switch off all power before camera movement or installation 2 3 Power Supply Caution It is recommended to use 12V DC 10 o...

Page 12: ...camera that can transfer 25M Pixel high resolution at a rate of 30fps 10Tap 25fps 8tap 12fps 4tap 6fps 2tap speed by applying Camera Link Interface and 10 Tap 8 Tap 4 Tap 2 Tap Full Configuration Mod...

Page 13: ...PS 2Tap Mono Output pixel format 8Bit 10Bit Defective pixel correction DPC Flat Field Correction FFC Adaptive PRNU Global shutter Analog Digital gain control Black Level compensation UART serial commu...

Page 14: ...ITA25K Trigger Mode Free Run External Trigger Pulse Width Trigger External Trigger Edge Preset Trigger Software Trigger Pulse Width Trigger Software Trigger Edge Preset Trigger External Trigger 3 3V 5...

Page 15: ...nual More than Imaging Laon People 15 2016 03 04 3 4 Sensor Information 3 4 1 Sensor Optical Chart Figure 1 LPMVC CL025M Sensor Optical Chart 3 5 Mechanical Specifications 3 5 1 Outline Figure 2 LPMVC...

Page 16: ...CL025M Manual More than Imaging Laon People 16 2016 03 04 3 5 2 FBL Flange Back Length F Mount Figure 3 LPMVC CL025M Flange Back Length F Mount Tripod Mount Plate Figure 4 LPMVC CL025M Tripod Mount P...

Page 17: ...guration data Camera Link Connector 2 26 Pin Mini D Ribbon MDR female connector used to transmit image data Status LED Dual Color LED used to display power camera operation status JTAG Connector USB M...

Page 18: ...pin female 1 27 MDR Camera Link Connector Applied Camera Link Connector observes the Camera Link Standard Figure 6 Table 2 3 shows the number of each pin and specific descriptions of the Camera Link...

Page 19: ...LPMVC CL025M Manual More than Imaging Laon People 19 2016 03 04 Table 3 Pin Assignments for LPMVC CL025M Camera Link Connector 2...

Page 20: ...ignment of LPMVC CL025M Figure 7 Description of each Data bits for 8Tap 8bit Data bit Description DA0 DA7 8bit data for Tap1 DB0 DB7 8bit data for Tap2 DC0 DC7 8bit data for Tap3 DD0 DD7 8bit data for...

Page 21: ...or Tap2 DC0 DC7 8bit data for Tap3 DD0 DD7 8bit data for Tap4 DE0 DE7 8bit data for Tap5 DF0 DF7 8bit data for Tap6 DG0 DG7 8bit data for Tap7 DH0 DH7 8bit data for Tap8 DI0 DI7 8bit data for Tap9 DJ0...

Page 22: ...LPMVC CL025M Manual More than Imaging Laon People 22 2016 03 04 Figure 9 Parallel Data Mapped to LVDS outs...

Page 23: ...LPMVC CL025M Manual More than Imaging Laon People 23 2016 03 04 Table 6 Camera Link TAP Port Assignments...

Page 24: ...gure 10 LPMVC CL025M Power Connector Pin Number Signal Name Type Function 1 2 3 DC 12V Input DC Power 4 5 6 GND Input DC Ground Table 7 Pin Assignments for LPMVC CL025M Power Connector The Power Plug...

Page 25: ...ut strobe output Pin arrangement and configuration are as follows Figure 11 LPMVC CL025M I O Connector Pin Number Signal Name Type Description 1 Trigger Input Input 2 Trigger Input Input 3 Strobe Outp...

Page 26: ...PGA JTAG used for updating FPGA firmware Pin arrangement and configuration are as follows Figure 12 LPMVC CL025M JTAG Connector Pin Number Signal Name Type Description 1 VREF Input Reference voltage 2...

Page 27: ...o the internal circuit through the photo coupler 1 is the minimum width of the trigger signal which the camera can recognize If the width of the trigger signal is shorter than 1 camera ignores this si...

Page 28: ...ut Circuit Figure 14 represents the strobe output circuit Strobe output signal is passed to the external I O connector through the photo coupler The width of strobe output signals are output in synchr...

Page 29: ...e LPMVC CL025M is possible by multiples of 128 and horizontal width is possible by multiples of 64 The starting position of the Y axis and Vertical width is possible by multiples of 2 5 2 Test Pattern...

Page 30: ...the exposure time beyond the scope of the set frame rate it is automatically changed to the maximum frame rate to satisfy the exposure time entered by the user so user should be careful Model LPMVC CL...

Page 31: ...nce of the illuminance in the sensor manufacturing process 5 8 Black Level Compensation If the temperature of the sensor rises the sharpness of the image quality will fall because of the Blurred Image...

Page 32: ...amera Output Timing Chart Figure 17 and 18 show the Horizontal Timing Chart of LPMVC CL025M Figure 19 and 20 show the Vertical Timing Chart of LPMVC CL025M 5 9 1 Horizontal Timing Chart Figure 18 Hori...

Page 33: ...LPMVC CL025M Manual More than Imaging Laon People 33 2016 03 04 Figure 20 Horizontal Timing Chart of 8Tap...

Page 34: ...LPMVC CL025M Manual More than Imaging Laon People 34 2016 03 04 Figure 21 Horizontal Timing Chart of 10Tap...

Page 35: ...LPMVC CL025M Manual More than Imaging Laon People 35 2016 03 04 5 9 2 Vertical Timing Chart Figure 22 Vertical Timing Chart of 2Tap Figure 23 Vertical Timing Chart of 4Tap...

Page 36: ...LPMVC CL025M Manual More than Imaging Laon People 36 2016 03 04 Figure 24 Vertical Timing Chart of 8Tap Figure 25 Vertical Timing Chart of 10Tap...

Page 37: ...from the External Trigger port or CC1 port of the camera Trigger Polarity This item decides to operate the camera in the Active High or in the Active Low when the trigger signal is input Pulse Width T...

Page 38: ...image data transmission time 5 10 2 External Sync Mode Pulse Width Trigger In the External Sync Mode the Camera maintains the standby status until the external trigger signal is input and then exposes...

Page 39: ...reset Trigger Mode User should select the Trigger Source by the External Trigger port or the CC1 port and should set the Sensor Exposure Time to the Edge Preset Trigger In Edge Preset Trigger Mode it...

Page 40: ...osure progress simultaneously In this mode the maximum frame rate of the camera can be used because it can be used effectively when the frame rate is very fast or the exposure time of the sensor is no...

Page 41: ...exposure Strobe Bypass Sync This item passes the CC3 external light signal as it is passed Strobe Polarity This item decides to operate the strobe signal as Active High or in the Active Low Strobe Del...

Page 42: ...ect the ad hoc input to the ad hoc output LUT is used to change the image s specific value to another value or change the brightness of image and so on LPMVC CL025M supports 8 LUT and user can make th...

Page 43: ...ure 27 Figure 32 CULaTor UART Select Dialog In this dialog box the physical COM Port which is searched in the user s computer and the List of the virtual COM Ports these are used in the CameraLink sta...

Page 44: ...maging Laon People 44 2016 03 04 If the communication with LPMVC CL025M is successful the the CULaTor will read the information of the camera and shows on the screen immediately after applying the inf...

Page 45: ...ll set values that user did not save will be canceled and the saved StartUp UserSet PRNU LUT are will be maintained Load UserSet from file This menu will load the UserSet file saved in shape of the in...

Page 46: ...the ini file This menu will be useful in the work environment in which a number of cameras use the same settings Save UserSet x This menu will saved in the UserSet All set values that user did not sa...

Page 47: ...mediately after the camera power is applied User can set the StartUp movement of the camera by selecting the item from Factory Default and 8 UserSet When the save is completed the StartUp save complet...

Page 48: ...LPMVC CL025M Manual More than Imaging Laon People 48 2016 03 04 6 2 3 About Figure 39 CULaTor About Menu Figure 40 CULaTor About Dialog Copyright Camera Image Tap CULaTor Version Camera Version...

Page 49: ...e output to 10 bit 6 3 2 View Mode Set the Playback Mode Normal Set the Normal Playback Mode rather than ROI Binning ROI Playback Mode that can increase the Frame Rate by setting the image output area...

Page 50: ...output 2 Tap 2 Tap output 6 3 5 ROI Set the region on the ROI X Start Y Start Set starting position of the ROI area Width Height Set horizontal vertical size of the ROI area QUARTER HALF Set the 1 4 o...

Page 51: ...mera If user raises the Analog Gain value of the camera the screen will be brighter than before The range of the Gain value that can be set are 0 1 2 3 6 4 2 Digital Gain Set the Digital Gain of the c...

Page 52: ...depending on the Frame Grabber So user should be careful The shorter the vertical length of the image is the higher the value of Frame Rate will become The default values differs depending on current...

Page 53: ...n be used in LPMVC CL025M The range of the Black Level Calibration values that can be set is 0 255 6 4 8 FILTER Sets the Defective Pixel Correction Function of the camera LPMVC CL025M support two DPC...

Page 54: ...ger Off Terminates the Trigger Mode External Trigger Use the Trigger Mode and the Input pin of I O port Board Control Trigger Use the Trigger Mode and the frame grabber s CC1 port 6 5 2 Trigger Polari...

Page 55: ...ter the set time has passed 6 5 5 Strobe Strobe On Use the external light source Sensor Exposure Sync Activates the external light source at the same time with the beginning of the sensor exposure Str...

Page 56: ...drive the Strobe before starting the exposure of the sensor this tab sets the interval time between the Strobe and the beginning of the sensor exposure time 6 5 8 Strobe Duration Set the duration tim...

Page 57: ...e user can change the output data from the particular area or all the brightness values of the output to the value of a user specified arbitrary image data Figure 46 CULaTor LUT Tab 6 6 1 LUT On Decid...

Page 58: ...ice is clicked on the CULaTor s LUT Tab the CULaTor opens save device dialog box User can select the LUT data and adjust the LUT sequence User can write the select LUT value to EEPROM Figure 47 CULaTo...

Page 59: ...LPMVC CL025M Manual More than Imaging Laon People 59 2016 03 04 6 6 7 Set to Linear Set the Knee Points as the default value The LUT formula that corresponds to the default value is y x...

Reviews: