Configuration via Serial Mode or Telnet Port
WiPort™ User Guide
57
Enable High Performance (N) ? _
Disable Monitor Mode
Disables entry into Monitor Mode via the 'yyy' or 'xx1' key sequence at startup. This
command prevents the unit from entering Monitor Mode by interpreting the stream of
characters that are received during the device server's initialization at startup. The
default is
N
(No).
Disable Monitor Mode @ bootup (N) ? _
HTTP Port Number
This option allows the configuration of the web server port number. The valid range
is 1-65535. The default HTTP server port number is 80.
HTTP Port Number : (80) ? _
SMTP Port Number
This option allows the configuration of the SMTP port number. The valid range is 1-
65535. The default HTTP server port number is 25.
SMTP Port Number : (25) ? _
Security Settings
Change security settings via Telnet or serial connections only, not on the Web-
Manager.
Note:
As recommended, set security over the dedicated network or over the
serial setup. If the parameters are set over the network (Telnet 9999),
someone else could capture these settings.
Caution:
Disabling both Telnet Setup and Port 77FE prevent users from
accessing the setup menu from the network.
Disable SNMP
For security purposes, disable SNMP (if required) on the WiPort unit. The current
setting is displayed in parentheses.
Disable SNMP (N) ? _
SNMP Community Name
The SNMP Community Name is a required field for NMS to read or write to a device.
Enter a string of 1 to 13 characters.
SNMP Community Name (public): _
The default entry is
public
. The current value is displayed in parentheses.
Disable Telnet Setup
Note:
If this option is disabled, note that disabling both Telnet Setup and Port
77FE prevents users from accessing the setup menu from the network.