Setup Mode: Channel Configuration
WiBox2100E User Guide
62
Trailing Characters
In some applications, CRC, Checksum, or other trailing characters follow the end-of-
sequence character; this option helps to adapt frame transmission to the frame
boundary. The default setting is
00
(none).
Send Characters
If
2-Byte Send Character Sequence
is enabled, the unit interprets the
sendchars as a 2-byte sequence; if this option is not enabled, the unit
interprets them independently. The default setting is
0
(disabled).
If
Send Immediately After Characters
is
not
set, any characters already in
the serial buffer are included in the transmission after a "transmit" condition is
found. If this option is set, the unit sends immediately after recognizing the
transmit condition (sendchar or timeout). The default setting is
0
.
Note:
A transmission might occur if status information needs to be
exchanged or an acknowledgment needs to be sent.
DisConnTime (Inactivity Timeout)
Use this parameter to set an inactivity timeout. The unit drops the connection if there
is no activity on the serial line before the set time expires. Enter time in the format
mm:ss, where m is the number of minutes and s is the number of seconds.
DisConnTime (00:00) ?:
To disable the inactivity timeout, enter
00:00
. Range is 0 (disabled) to
5999
seconds
(99 minutes, 59 seconds). The default setting is
0
.
Send Characters
Enter up to two characters in hexadecimal representation in sendchar.
SendChar 1 (00) ? _
SendChar 2 (00) ? _
If the unit receives a character on the serial line that matches one of these
characters, it sends the character immediately, along with any awaiting characters, to
the TCP connection. This action minimizes the response time for specific protocol
characters on the serial line (for example, ETX, EOT). Setting the first sendchar to
00
disables the recognition of the characters. Alternatively, the unit can interpret two
characters as a sequence (see
Pack Control
on page 61). The default setting is
00.
Telnet Terminal Type
This parameter displays only if you enabled the terminal type option in Disconnect
Mode. With this option enabled, you can use the terminal name for the Telnet
terminal type. Enter only one name.
With terminal type option enabled, the unit also reacts to the EOR (end of record) and
binary options, useful for applications like terminal emulation to IBM hosts.