7: Setup Mode: Channel Configuration
WiBox® 2100E Device Server User Guide
60
Table 7-9. Disconnect Mode Options
Disconnect Mode Option
7
6
5
4
3
2
1
0
Disconnect when Modem Control In is not
asserted
(6)
1
Ignore Modem Control In
0
Telnet Com Port Cntrl and terminal type setup
(1)
1
Channel (port) password
(2)
1
Hard disconnect
(3)
0
Disable hard disconnect
1
State LED off with connection
(4)
1
Disconnect with EOT (^D)
(5)
1
(1) The WiBox 2100E sends the "Terminal Type" upon an outgoing connection.
(2) A password is required for a connection to the serial port from the network.
(3) The TCP connection closes even if the remote site does not acknowledge the disconnection.
(4) When there is a network connection to or from the serial port, the state LED turns off instead of
blinking.
(5) When
Ctrl+D
or
Hex 04
is detected, the connection is dropped. Both
Telnet Com Port Cntrl
and
Disconnect with EOT
must be enabled for
Disconnect with EOT
to function properly.
Ctrl+D
is only
detected going from the serial port to the network.
(6) When
Modem Control In
transitions from a high state to a low state, the network connection to or
from the serial port drops.
Flush Mode (Buffer Flushing)
Using this parameter, you can control line handling and network buffers with connection startup
and disconnect. The default setting is
00
.
FlushMode (00) ? _
You can also select between two different packing algorithms.
Note:
All bit positions in the table that are blank represent “don’t care” bits for that
particular option; they can be set to either a 0 or 1 value.
Table 7-10. Flush Mode Options
Function
7
6
5
4
3 2 1
0
Input Buffer (Serial to Network)
Clear with a connection initiated from the device to the network
1
Clear with a connection initiated from the network to the device
1