General Specifications
Specification
Min.
Typ.
Max.
Unit of Measure
Efficiency
≥ 87.59
%
IR
≥ 50
MΩ
Leakage Current
≥ 500
uA
Voltage Isolation
: DC ground may be separated from AC neutral and AC line.
Insulation Test
: Between primary and secondary circuit: 500VDC, 2 Sec.
Configuration
: Line, Neutral: 2-Wire, AC Input.
Hi-Pot Test
: Between primary and secondary circuit: 3000VAC/4242VDC, 3mA 2 Sec.
Drop Out
: Output voltage should remain in specified range, through the absence of line input during ½ cycle, at full
load and normal AC line input.
Physical Specifications
Weight
: 10.58 Oz (300 Gr.)
Dimensions
: 4.45 in x 1.93 In. x 1.38 In. (113mm x 49mm x 35mm)
Enclosure Material: 94V-0 Minimum
Output
Cable
: UL2468#20
Safety Characteristics
Safety Approvals
UL, CUL, CB, CE, FCC, RCM, BSMI, IRAM,
CCC
EMI
CISPR 32, EN 55032
FCCP Part 15
Class B
Class B
ESD
IEC 61-000-4-2
Contact: ±4kV
Air: ±8kV
RS
IEC 61-000-4-3
Frequency: 80~1000MHz
Field Strength: 3V/M, 80% AM (1KHz)
EFT
IEC 61-000-4-4
1.0KV on Input Power Ports
Surge
IEC 61-000-4-5
Line to Line: ±1kV (peak)
Efficiency
Energy Star Ver. 2.0, DoE Level VI,
ErP STEP2
Note