LTR-T Installation Guide
Appendix A-23
Appendix A: Power Supply Cord
Cord type:
3 conductors
1.0 mm
2
minimum conductor size (approx. 18 AWG)
Rated for 250 Volts AC, 10 Amps
Length
≤
3.0 meters (10 feet)
The cord should have a harmonized cable type number. (“Harmonized” refers to an
internationally standardized cable description, and is prefixed by the letters HAR.) An
example of a valid harmonized cord type is:
HAR HO5VV-F 3G1.00
Connectors: The cord should terminate in a molded-on IEC 320-C13 female connector
body at one end for proper interface to the LTR-T. The other end should be of a plug
configuration appropriate to the country in question.
Grounding Warning: To reduce the risk of electric shock, in countries using an IT
power system or where protective earth ground connection is not made, the ground
conductor of the power cable should be connected to earth ground.
Approvals: The cord connectors should bear the approval mark of at least one of the
following regulatory and safety agencies:
EMA
EUR
K
Netherlands (KEMA)
N
Norway (NEMKO)
NF
France (UTE)
(Note: The above symbols are approximate representations of the actual
approval symbols, and are for the user's reference only.)
Austria (OVE)
OVE
Switzerland (SEV)
+
S
Sweden (SEMKO)
Finland (EI)
FI
Germany (VDE)
V
D E
United Kingdom (BSI)
Denmark (DEMKO)
D
United Kingdom (ASTA)
T
ASA
BS 5750
ASSESSED
QUALITY
Belgium (CEBEC)
CEBEC
Italy (IMQ)