LTR-T Installation Guide
3
Voltage
95-250 Vac 3-wire single phase, autoranging
Frequency
47 to 63 Hz
Operating current
0.5 Amp (maximum)
Power
30 Watts
Fuse (field replaceable)
2 Amp 250 Vac, time delay
Table 1: LTR-T Power Requirements
Fuse
Under normal use, the fuse should not need to be replaced. If it does, ensure that the
proper type of fuse is used. Never replace the fuse with the unit plugged in.
*** CAUTION: For continued protection against the risk of fire, replace only with the
same type and rating of fuse: T2A/250V.
*** AVIS: Pour la protection continuante contre le risque d’incendie remplacer
seulement par le même type et le cote de fusible: T2A/250V.
*** VORSICHT: Zum Schutz gegen das Risiko eines Brandes darf die Sicherung nur mit
einer mit gleichen technischen Daten ersetzt werden: T2A / 250V.
Temperature Limitations
• Operating: 5
°
to 50
°
C (41
°
to 122
°
F)
• Nonoperating: -40
°
to 66
°
C (-40
°
to 151
°
F)
Rapid temperature changes may affect operation. Therefore, do not operate the LTR-T
near heating or cooling devices, large windows, or doors that open to the outside.
Maximum temperature change per hour is 20
°
C (36
°
F).
Altitude Limitations
• Operating: 2.4 km (8,000 ft.)
• Nonoperating: 9.1 km (30,000 ft.)
If you are operating the LTR-T above 2.4 km (8,000 ft.), decrease the operating
temperature by 1.8
°
C for each additional 1,000 m (1
°
F for each 1,000 ft.).
Relative Humidity Limitations
• Operating: 10% to 90% noncondensing (40% to 60% recommended)
• Nonoperating: 10% to 90% noncondensing