Chapter 4:
The Flow Chart
The flow chart section contains all flow chart used in the
system. The flow chart describes the system’s behavior
on powering on and off the system via power ignition
control or on/off switch when the appropriate timer
control parameters are set.
Note:
For power-good and low-voltage
1.
mechanism to function in the workflow,
you will need to enable the power-good
and low-voltage detection function
with
selector 1
and
selector 2
jumper
respectively of
SW1
. (Refer to
Chapter 3
Board Layout
).
For power on and power off delay timer
2.
parameter, refer to
Appendix A Using the
Ignition System Manager (ISM)
.
For DI wake-up function, refer to jumper
3.
MIO2
Pin NO.19
and
21
. Refer to
Chapter
3 Board Layout
and
Appendix A Using
the Ignition System Manager (ISM)
for
jumper setting and parameter setting
respectively.
When the system’s shutdown timer starts
4.
counting down 180sec, using ignition
or External PWR_BTN to start the system
again during shutdown process will not
work until the countdown finishes.